Title: Flammable Refrigerant Charge Limits: Can or Should These Limits Be Higher?

A workshop was held to discuss different aspects of the application of flammable refrigerants in refrigeration and air conditioning equipment. The participants included stakeholders from industry, regulatory bodies, and the scientific community. The goal was to solicit feedback on the critical scientific, regulatory and practical issues for safe employment of flammable refrigerants in heating, ventilation, air- conditioning and refrigeration equipment. This paper reports on the outcome of the workshop and presents review of relevant past studies when available. The reported outcome may serve well as a guide to further research needed as adoption of flammable refrigerants increases.
Authors:
ORCiD logo [1] ; ORCiD logo [1] ; ORCiD logo [1] ; ORCiD logo [1] ; ORCiD logo [1]
  1. Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
Publication Date:
Grant/Contract Number:
AC05-00OR22725
Type:
Accepted Manuscript
Journal Name:
ASHRAE Journal
Additional Journal Information:
Journal Volume: 60; Journal Issue: 7; Journal ID: ISSN 0001-2491
Publisher:
American Society of Heating, Refrigerating and Air-Conditioning Engineers
Research Org:
Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
Sponsoring Org:
USDOE Office of Energy Efficiency and Renewable Energy (EERE)
Country of Publication:
United States
Language:
English
Subject:
42 ENGINEERING
OSTI Identifier:
1459281

Abu-Heiba, Ahmad, Patel, Viral K., Baxter, Van D., Abdelaziz, Omar, and Elatar, Ahmed F.. Flammable Refrigerant Charge Limits: Can or Should These Limits Be Higher?. United States: N. p., Web.
Abu-Heiba, Ahmad, Patel, Viral K., Baxter, Van D., Abdelaziz, Omar, & Elatar, Ahmed F.. Flammable Refrigerant Charge Limits: Can or Should These Limits Be Higher?. United States.
Abu-Heiba, Ahmad, Patel, Viral K., Baxter, Van D., Abdelaziz, Omar, and Elatar, Ahmed F.. 2018. "Flammable Refrigerant Charge Limits: Can or Should These Limits Be Higher?". United States. doi:.
@article{osti_1459281,
title = {Flammable Refrigerant Charge Limits: Can or Should These Limits Be Higher?},
author = {Abu-Heiba, Ahmad and Patel, Viral K. and Baxter, Van D. and Abdelaziz, Omar and Elatar, Ahmed F.},
abstractNote = {A workshop was held to discuss different aspects of the application of flammable refrigerants in refrigeration and air conditioning equipment. The participants included stakeholders from industry, regulatory bodies, and the scientific community. The goal was to solicit feedback on the critical scientific, regulatory and practical issues for safe employment of flammable refrigerants in heating, ventilation, air- conditioning and refrigeration equipment. This paper reports on the outcome of the workshop and presents review of relevant past studies when available. The reported outcome may serve well as a guide to further research needed as adoption of flammable refrigerants increases.},
doi = {},
journal = {ASHRAE Journal},
number = 7,
volume = 60,
place = {United States},
year = {2018},
month = {7}
}