Title: Wireless Monitoring of Liver Hemodynamics In Vivo

Abstract

Liver transplants have their highest failure rate in the first two weeks following surgery. There are no devices for continuous, real-time monitoring of the graft, currently. Here, we present a continuous perfusion and oxygen consumption monitor based on photoplethysmography. The sensor is battery operated and communicates wirelessly with a data acquisition computer which provides the possibility of implantation provided sufficient miniaturization. In two in vivo porcine studies, the sensor tracked perfusion changes in hepatic tissue during vascular occlusions with a root mean square error (RMSE) of 0.125 mL/min/g of tissue. We show the possibility of using the pulsatile wave to measure the arterial oxygen saturation similar to pulse oximetry. This signal is used as a feedback to extract the venous oxygen saturation from the DC levels. Arterial and venous oxygen saturation changes were measured with an RMSE of 2.19 and 1.39% respectively when no vascular occlusions were induced. The resulting error increased to 2.82 and 3.83% when vascular occlusions were induced during hypoxia. These errors are similar to the resolution of the oximetry catheter used as a reference. This work is the first realization of a wireless perfusion and oxygenation sensor for continuous monitoring of hepatic perfusion and oxygenation changes.

Authors:
 [1];  [2];  [3];  [3];  [1];  [4]
  1. Texas A & M Univ., College Station, TX (United States). Dept. of Biomedical Engineering
  2. Univ. of Pittsburgh, PA (United States). Dept. of Surgery; Veterans Affairs Healthcare System, Pittsburgh, PA (United States)
  3. Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
  4. Univ. of California, Irvine, CA (United States)
Publication Date:
Research Org.:
Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
Sponsoring Org.:
National Institutes of Health (NIH)
OSTI Identifier:
1366361
Grant/Contract Number:  
AC05-00OR22725; #5R01-GM077150
Resource Type:
Accepted Manuscript
Journal Name:
PLoS ONE
Additional Journal Information:
Journal Volume: 9; Journal Issue: 7; Journal ID: ISSN 1932-6203
Publisher:
Public Library of Science
Country of Publication:
United States
Language:
English
Subject:
60 APPLIED LIFE SCIENCES; 59 BASIC BIOLOGICAL SCIENCES; Liver; perfusion monitoring; oxygenation; wireless sensing

Citation Formats

Akl, Tony J., Wilson, Mark A., Ericson, M. Nance, Farquhar, Ethan, Cote, Gerard L., and Brody, James P. Wireless Monitoring of Liver Hemodynamics In Vivo. United States: N. p., 2014. Web. doi:10.1371/journal.pone.0102396.
Akl, Tony J., Wilson, Mark A., Ericson, M. Nance, Farquhar, Ethan, Cote, Gerard L., & Brody, James P. Wireless Monitoring of Liver Hemodynamics In Vivo. United States. https://doi.org/10.1371/journal.pone.0102396
Akl, Tony J., Wilson, Mark A., Ericson, M. Nance, Farquhar, Ethan, Cote, Gerard L., and Brody, James P. Mon . "Wireless Monitoring of Liver Hemodynamics In Vivo". United States. https://doi.org/10.1371/journal.pone.0102396. https://www.osti.gov/servlets/purl/1366361.
@article{osti_1366361,
title = {Wireless Monitoring of Liver Hemodynamics In Vivo},
author = {Akl, Tony J. and Wilson, Mark A. and Ericson, M. Nance and Farquhar, Ethan and Cote, Gerard L. and Brody, James P.},
abstractNote = {Liver transplants have their highest failure rate in the first two weeks following surgery. There are no devices for continuous, real-time monitoring of the graft, currently. Here, we present a continuous perfusion and oxygen consumption monitor based on photoplethysmography. The sensor is battery operated and communicates wirelessly with a data acquisition computer which provides the possibility of implantation provided sufficient miniaturization. In two in vivo porcine studies, the sensor tracked perfusion changes in hepatic tissue during vascular occlusions with a root mean square error (RMSE) of 0.125 mL/min/g of tissue. We show the possibility of using the pulsatile wave to measure the arterial oxygen saturation similar to pulse oximetry. This signal is used as a feedback to extract the venous oxygen saturation from the DC levels. Arterial and venous oxygen saturation changes were measured with an RMSE of 2.19 and 1.39% respectively when no vascular occlusions were induced. The resulting error increased to 2.82 and 3.83% when vascular occlusions were induced during hypoxia. These errors are similar to the resolution of the oximetry catheter used as a reference. This work is the first realization of a wireless perfusion and oxygenation sensor for continuous monitoring of hepatic perfusion and oxygenation changes.},
doi = {10.1371/journal.pone.0102396},
journal = {PLoS ONE},
number = 7,
volume = 9,
place = {United States},
year = {Mon Jul 14 00:00:00 EDT 2014},
month = {Mon Jul 14 00:00:00 EDT 2014}
}

Journal Article:
Free Publicly Available Full Text
Publisher's Version of Record

Citation Metrics:
Cited by: 6 works
Citation information provided by
Web of Science

Save / Share:

Works referenced in this record:

Hemoglobin Oxygenation Kinetics and Secondary Ischemia in Renal Transplantation1
journal, March 1996


An Autocorrelation-Based Time Domain Analysis Technique for Monitoring Perfusion and Oxygenation in Transplanted Organs
journal, July 2005

  • Subramanian, H.; Ibey, B. L.; Xu, W.
  • IEEE Transactions on Biomedical Engineering, Vol. 52, Issue 7
  • DOI: 10.1109/TBME.2005.847552

A custom electronics platform for implantable perfusion sensor development
conference, November 2011

  • Ericson, M. N.; Frank, S. S.; Britton, C. L.
  • 2011 Future of Instrumentation International Workshop (FIIW) Proceedings
  • DOI: 10.1109/FIIW.2011.6476801

Thermal Diffusion Probe Analysis of Perfusion Changes in Vascular Occlusions of Rabbit Pedicle Flaps
journal, April 2005


Implantable sensor for blood flow monitoring after transplant surgery
journal, January 2004

  • Ericson, M. N.; Wilson, M. A.; Coté, G. L.
  • Minimally Invasive Therapy & Allied Technologies, Vol. 13, Issue 2
  • DOI: 10.1080/13645700410027866

Cause and timing of first allograft failure in orthotopic liver transplantation: A study of 177 consecutive patients
journal, December 1991

  • Quiroga, Jorge; Colina, Inmaculada; Demetris, A. Jake
  • Hepatology, Vol. 14, Issue 6
  • DOI: 10.1002/hep.1840140618

Signal processing methods for pulse oximetry
journal, March 1996


Early assessment of reperfusion injury by intraoperative quantification of hepatic microcirculation in patients
journal, February 1997


Blood lactate accumulation and muscle deoxygenation during incremental exercise
journal, July 1999

  • Grassi, Bruno; Quaresima, Valentina; Marconi, Claudio
  • Journal of Applied Physiology, Vol. 87, Issue 1
  • DOI: 10.1152/jappl.1999.87.1.348

Simultaneous in-situNIRS of liver and bowel during septic shock
journal, January 2006

  • Gagnon, R. E.; Hahum, E.; Skarsgard, E.
  • Spectroscopy, Vol. 20, Issue 5-6
  • DOI: 10.1155/2006/285157

Influence of oxygen saturation on the optical scattering properties of human red blood cells in the spectral range 250 to 2000 nm
journal, January 2009

  • Friebel, Moritz; Helfmann, Jürgen; Netz, Uwe
  • Journal of Biomedical Optics, Vol. 14, Issue 3
  • DOI: 10.1117/1.3127200

Performance assessment of an opto-fluidic phantom mimicking porcine liver parenchyma
journal, July 2012


First clinical realization of continuous monitoring of liver microcirculation after transplantation by thermodiffusion
journal, August 1996


Noninvasive Monitoring by Photoplethysmography
journal, September 2012


Arterial and Venous Contributions to Near-infrared Cerebral Oximetry
journal, October 2000


Arterial and Venous Contributions to Near-infrared Cerebral Oximetry
journal, October 2000


Wavelength selection for low-saturation pulse oximetry
journal, March 1997

  • Mannheimer, P. D.; Cascini, J. R.; Fein, M. E.
  • IEEE Transactions on Biomedical Engineering, Vol. 44, Issue 3
  • DOI: 10.1109/10.554761

The relationship of systemic hemodynamics and oxygen consumption to early allograft failure after liver transplantation
journal, March 1993

  • Takaya, S.; Nonami, T.; Selby, R.
  • Transplant International, Vol. 6, Issue 2
  • DOI: 10.1007/bf00336648

Laser Doppler perfusion monitoring and imaging: novel approaches
journal, March 2007

  • Humeau, Anne; Steenbergen, Wiendelt; Nilsson, Henrik
  • Medical & Biological Engineering & Computing, Vol. 45, Issue 5
  • DOI: 10.1007/s11517-007-0170-5

Validation of a new transit time ultrasound flowmeter in man
journal, July 1996

  • Laustsen, J.; Pedersen, E. M.; Terp, K.
  • European Journal of Vascular and Endovascular Surgery, Vol. 12, Issue 1
  • DOI: 10.1016/S1078-5884(96)80282-6

A noninvasive estimation of mixed venous oxygen saturation using near-infrared spectroscopy by cerebral oximetry in pediatric cardiac surgery patients
journal, June 2005


Near infrared spectroscopy (NIRS) of the thenar eminence in anesthesia and intensive care
journal, May 2012

  • Lipcsey, Miklos; Woinarski, Nicholas CZ; Bellomo, Rinaldo
  • Annals of Intensive Care, Vol. 2, Issue 1
  • DOI: 10.1186/2110-5820-2-11

The Accuracy of Near Infrared Spectroscopy and Imaging during Focal Changes in Cerebral Hemodynamics
journal, January 2001


A noninvasive estimation of mixed venous oxygen saturation using near-infrared spectroscopy by cerebral oximetry in pediatric cardiac surgery patients
journal, June 2005


Optimizing probe design for an implantable perfusion and oxygenation sensor
journal, June 2011

  • Akl, Tony J.; Long, Ruiqi; McShane, Michael J.
  • Biomedical Optics Express, Vol. 2, Issue 8
  • DOI: 10.1364/BOE.2.002096

Laser Doppler perfusion monitoring and imaging: novel approaches
journal, March 2007

  • Humeau, Anne; Steenbergen, Wiendelt; Nilsson, Henrik
  • Medical & Biological Engineering & Computing, Vol. 45, Issue 5
  • DOI: 10.1007/s11517-007-0170-5

Changes in tissue oxygenation of the porcine liver measured by near-infrared spectroscopy
journal, May 1999

  • El-Desoky, Abd El; Seifalian, Alexander; Cope, Mark
  • Liver Transplantation and Surgery, Vol. 5, Issue 3
  • DOI: 10.1002/lt.500050316

Changes in tissue oxygenation of the porcine liver measured by near-infrared spectroscopy
journal, May 1999

  • El-Desoky, Abd El; Seifalian, Alexander; Cope, Mark
  • Liver Transplantation and Surgery, Vol. 5, Issue 3
  • DOI: 10.1002/lt.500050316

Noninvasive Monitoring by Photoplethysmography
journal, September 2012


Real-Time Separation of Perfusion and Oxygenation Signals for an Implantable Sensor Using Adaptive Filtering
journal, December 2005

  • Subramanian, H.; Ibey, B. L.; Xu, W.
  • IEEE Transactions on Biomedical Engineering, Vol. 52, Issue 12
  • DOI: 10.1109/TBME.2005.857667

The relationship of systemic hemodynamics and oxygen consumption to early allograft failure after liver transplantation
journal, March 1993


Simultaneous in-situNIRS of liver and bowel during septic shock
journal, January 2006

  • Gagnon, R. E.; Hahum, E.; Skarsgard, E.
  • Spectroscopy, Vol. 20, Issue 5-6
  • DOI: 10.1155/2006/285157

Implantable sensor for blood flow monitoring after transplant surgery
journal, January 2004

  • Ericson, M. N.; Wilson, M. A.; Coté, G. L.
  • Minimally Invasive Therapy & Allied Technologies, Vol. 13, Issue 2
  • DOI: 10.1080/13645700410027866

Blood lactate accumulation and muscle deoxygenation during incremental exercise
journal, July 1999

  • Grassi, Bruno; Quaresima, Valentina; Marconi, Claudio
  • Journal of Applied Physiology, Vol. 87, Issue 1
  • DOI: 10.1152/jappl.1999.87.1.348

Works referencing / citing this record:

High-throughput and automated diagnosis of antimicrobial resistance using a cost-effective cellphone-based micro-plate reader
journal, December 2016

  • Feng, Steve; Tseng, Derek; Di Carlo, Dino
  • Scientific Reports, Vol. 6, Issue 1
  • DOI: 10.1038/srep39203