skip to main content

DOE PAGESDOE PAGES

Title: Status of the Perpendicular Biased 2nd Harmonic Cavity for the Fermilab Booster

This is a status report on the 2nd harmonic cavity for the Fermilab Booster as part of the Proton Improvement Plan (PIP) for increasing beam transmission efficiency, and thus reducing losses. A set of tuner rings has been procured and is undergoing quality control tests. The Y567 tube for driving the cavity has been successfully tested at both injection and extraction frequencies. A cooling scheme for the tuner and cavity has been developed after a thorough thermal analysis of the system. RF windows have been procured and substantial progress has been made on the mechanical designs of the cavity and the bias solenoid. Finally, the goal is to have a prototype cavity ready for testing by the end of 2017.
Authors:
 [1] ;  [1] ;  [1] ;  [1] ;  [1] ;  [1] ;  [1] ;  [1] ;  [1] ;  [1] ;  [1] ;  [1]
  1. Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
Publication Date:
Report Number(s):
FERMILAB-CONF-17-137-AD; IPAC-2017-THPIK115
1600150
Grant/Contract Number:
AC02-07CH11359
Type:
Accepted Manuscript
Journal Name:
Proceedings of the 8th International Particle Accelerator Conference
Additional Journal Information:
Conference: IPAC2017, Copenhagen (Denmark), 18 May 2017
Research Org:
Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
Sponsoring Org:
USDOE
Country of Publication:
United States
Language:
English
Subject:
42 ENGINEERING
OSTI Identifier:
1358090

Tan, C. Y., Dey, J. E., Duel, K. L., Kuharik, J. C., Madrak, R. L., Makarov, A., Pellico, W. A., Reid, J. S., Romanov, G., Slabaugh, M., Sun, D., and Terechkine, I.. Status of the Perpendicular Biased 2nd Harmonic Cavity for the Fermilab Booster. United States: N. p., Web. doi:10.18429/JACoW-IPAC2017-THPIK115.
Tan, C. Y., Dey, J. E., Duel, K. L., Kuharik, J. C., Madrak, R. L., Makarov, A., Pellico, W. A., Reid, J. S., Romanov, G., Slabaugh, M., Sun, D., & Terechkine, I.. Status of the Perpendicular Biased 2nd Harmonic Cavity for the Fermilab Booster. United States. doi:10.18429/JACoW-IPAC2017-THPIK115.
Tan, C. Y., Dey, J. E., Duel, K. L., Kuharik, J. C., Madrak, R. L., Makarov, A., Pellico, W. A., Reid, J. S., Romanov, G., Slabaugh, M., Sun, D., and Terechkine, I.. 2017. "Status of the Perpendicular Biased 2nd Harmonic Cavity for the Fermilab Booster". United States. doi:10.18429/JACoW-IPAC2017-THPIK115. https://www.osti.gov/servlets/purl/1358090.
@article{osti_1358090,
title = {Status of the Perpendicular Biased 2nd Harmonic Cavity for the Fermilab Booster},
author = {Tan, C. Y. and Dey, J. E. and Duel, K. L. and Kuharik, J. C. and Madrak, R. L. and Makarov, A. and Pellico, W. A. and Reid, J. S. and Romanov, G. and Slabaugh, M. and Sun, D. and Terechkine, I.},
abstractNote = {This is a status report on the 2nd harmonic cavity for the Fermilab Booster as part of the Proton Improvement Plan (PIP) for increasing beam transmission efficiency, and thus reducing losses. A set of tuner rings has been procured and is undergoing quality control tests. The Y567 tube for driving the cavity has been successfully tested at both injection and extraction frequencies. A cooling scheme for the tuner and cavity has been developed after a thorough thermal analysis of the system. RF windows have been procured and substantial progress has been made on the mechanical designs of the cavity and the bias solenoid. Finally, the goal is to have a prototype cavity ready for testing by the end of 2017.},
doi = {10.18429/JACoW-IPAC2017-THPIK115},
journal = {Proceedings of the 8th International Particle Accelerator Conference},
number = ,
volume = ,
place = {United States},
year = {2017},
month = {5}
}