DOE PAGES title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Optimizing detector geometry for trace element mapping by X-ray fluorescence

Abstract

We report that trace metals play critical roles in a variety of systems, ranging from cells to photovoltaics. X-Ray Fluorescence (XRF) microscopy using X-ray excitation provides one of the highest sensitivities available for imaging the distribution of trace metals at sub-100 nm resolution. With the growing availability and increasing performance of synchrotron light source based instruments and X-ray nanofocusing optics, and with improvements in energy-dispersive XRF detectors, what are the factors that limit trace element detectability? To address this question, we describe an analytical model for the total signal incident on XRF detectors with various geometries, including the spectral response of energy dispersive detectors. This model agrees well with experimentally recorded X-ray fluorescence spectra, and involves much shorter calculation times than with Monte Carlo simulations. With such a model, one can estimate the signal when a trace element is illuminated with an X-ray beam, and when just the surrounding non-fluorescent material is illuminated. From this signal difference, a contrast parameter can be calculated and this can in turn be used to calculate the signal-to-noise ratio (S/N) for detecting a certain elemental concentration. We apply this model to the detection of trace amounts of zinc in biological materials, and to themore » detection of small quantities of arsenic in semiconductors. In conclusion, we conclude that increased detector collection solid angle is (nearly) always advantageous even when considering the scattered signal. However, given the choice between a smaller detector at 90° to the beam versus a larger detector at 180° (in a backscatter-like geometry), the 90° detector is better for trace element detection in thick samples, while the larger detector in 180° geometry is better suited to trace element detection in thin samples.« less

Authors:
 [1];  [2];  [3];  [4];  [2]
  1. Northwestern Univ., Evanston, IL (United States)
  2. Argonne National Lab. (ANL), Argonne, IL (United States)
  3. Argonne National Lab. (ANL), Argonne, IL (United States); Northwestern Univ., Evanston, IL (United States)
  4. Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)
Publication Date:
Research Org.:
Argonne National Laboratory (ANL), Argonne, IL (United States)
Sponsoring Org.:
USDOE Office of Science (SC), Basic Energy Sciences (BES)
OSTI Identifier:
1257639
Alternate Identifier(s):
OSTI ID: 1247819
Grant/Contract Number:  
AC02-06CH11357; R01GM104530
Resource Type:
Accepted Manuscript
Journal Name:
Ultramicroscopy
Additional Journal Information:
Journal Volume: 152; Journal Issue: C; Journal ID: ISSN 0304-3991
Publisher:
Elsevier
Country of Publication:
United States
Language:
English
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; detector geometry; signal-to-noise ratio; trace element detection; X-ray fluorescence; X-ray fluorescence microscopy

Citation Formats

Sun, Yue, Gleber, Sophie -Charlotte, Jacobsen, Chris, Kirz, Janos, and Vogt, Stefan. Optimizing detector geometry for trace element mapping by X-ray fluorescence. United States: N. p., 2015. Web. doi:10.1016/j.ultramic.2014.12.014.
Sun, Yue, Gleber, Sophie -Charlotte, Jacobsen, Chris, Kirz, Janos, & Vogt, Stefan. Optimizing detector geometry for trace element mapping by X-ray fluorescence. United States. https://doi.org/10.1016/j.ultramic.2014.12.014
Sun, Yue, Gleber, Sophie -Charlotte, Jacobsen, Chris, Kirz, Janos, and Vogt, Stefan. Thu . "Optimizing detector geometry for trace element mapping by X-ray fluorescence". United States. https://doi.org/10.1016/j.ultramic.2014.12.014. https://www.osti.gov/servlets/purl/1257639.
@article{osti_1257639,
title = {Optimizing detector geometry for trace element mapping by X-ray fluorescence},
author = {Sun, Yue and Gleber, Sophie -Charlotte and Jacobsen, Chris and Kirz, Janos and Vogt, Stefan},
abstractNote = {We report that trace metals play critical roles in a variety of systems, ranging from cells to photovoltaics. X-Ray Fluorescence (XRF) microscopy using X-ray excitation provides one of the highest sensitivities available for imaging the distribution of trace metals at sub-100 nm resolution. With the growing availability and increasing performance of synchrotron light source based instruments and X-ray nanofocusing optics, and with improvements in energy-dispersive XRF detectors, what are the factors that limit trace element detectability? To address this question, we describe an analytical model for the total signal incident on XRF detectors with various geometries, including the spectral response of energy dispersive detectors. This model agrees well with experimentally recorded X-ray fluorescence spectra, and involves much shorter calculation times than with Monte Carlo simulations. With such a model, one can estimate the signal when a trace element is illuminated with an X-ray beam, and when just the surrounding non-fluorescent material is illuminated. From this signal difference, a contrast parameter can be calculated and this can in turn be used to calculate the signal-to-noise ratio (S/N) for detecting a certain elemental concentration. We apply this model to the detection of trace amounts of zinc in biological materials, and to the detection of small quantities of arsenic in semiconductors. In conclusion, we conclude that increased detector collection solid angle is (nearly) always advantageous even when considering the scattered signal. However, given the choice between a smaller detector at 90° to the beam versus a larger detector at 180° (in a backscatter-like geometry), the 90° detector is better for trace element detection in thick samples, while the larger detector in 180° geometry is better suited to trace element detection in thin samples.},
doi = {10.1016/j.ultramic.2014.12.014},
journal = {Ultramicroscopy},
number = C,
volume = 152,
place = {United States},
year = {Thu Jan 01 00:00:00 EST 2015},
month = {Thu Jan 01 00:00:00 EST 2015}
}

Journal Article:

Citation Metrics:
Cited by: 27 works
Citation information provided by
Web of Science

Save / Share:

Works referenced in this record:

X-ray fluorescence microprobe imaging in biology and medicine
journal, January 2006

  • Paunesku, Tatjana; Vogt, Stefan; Maser, Jörg
  • Journal of Cellular Biochemistry, Vol. 99, Issue 6
  • DOI: 10.1002/jcb.21047

Biological applications of X-ray fluorescence microscopy: exploring the subcellular topography and speciation of transition metals
journal, April 2007


X-ray fluorescence spectrometry, an analytical tool in neurochemical research
journal, January 2008

  • Szczerbowska-Boruchowska, Magdalena
  • X-Ray Spectrometry, Vol. 37, Issue 1
  • DOI: 10.1002/xrs.1007

Hard X-ray fluorescence tomography—an emerging tool for structural visualization
journal, October 2010


Trends in environmental science using microscopic X-ray fluorescence
journal, August 2011

  • Fittschen, Ursula Elisabeth Adriane; Falkenberg, Gerald
  • Spectrochimica Acta Part B: Atomic Spectroscopy, Vol. 66, Issue 8
  • DOI: 10.1016/j.sab.2011.06.006

Applications of synchrotron μ-XRF to study the distribution of biologically important elements in different environmental matrices: A review
journal, November 2012

  • Majumdar, Sanghamitra; Peralta-Videa, Jose R.; Castillo-Michel, Hiram
  • Analytica Chimica Acta, Vol. 755
  • DOI: 10.1016/j.aca.2012.09.050

Elemental and Chemically Specific X-ray Fluorescence Imaging of Biological Systems
journal, January 2014

  • Pushie, M. Jake; Pickering, Ingrid J.; Korbas, Malgorzata
  • Chemical Reviews, Vol. 114, Issue 17
  • DOI: 10.1021/cr4007297

Engineering metal-impurity nanodefects for low-cost solar cells
journal, August 2005

  • Buonassisi, Tonio; Istratov, Andrei A.; Marcus, Matthew A.
  • Nature Materials, Vol. 4, Issue 9
  • DOI: 10.1038/nmat1457

Nanoprobe X-ray fluorescence characterization of defects in large-area solar cells
journal, January 2011

  • Bertoni, M. I.; Fenning, D. P.; Rinio, M.
  • Energy & Environmental Science, Vol. 4, Issue 10
  • DOI: 10.1039/c1ee02083h

PIXE: a novel technique for elemental analysis
journal, January 1989


Quantitative trace element imaging using PIXE and the nuclear microprobe
journal, January 2000

  • Ryan, C. G.
  • International Journal of Imaging Systems and Technology, Vol. 11, Issue 4
  • DOI: 10.1002/ima.1007

Calcium measurements with electron probe X-ray and electron energy loss analysis.
journal, March 1990

  • LeFurgey, A.; Ingram, P.
  • Environmental Health Perspectives, Vol. 84
  • DOI: 10.1289/ehp.908457

Comparative Analysis of X-Ray Emission Microscopies for Biological Specimens
journal, March 1978


Mapping the Distribution of Particular Atomic Species
journal, June 1980


X-ray fluorescence with synchrotron radiation
journal, January 1988


Geant4—a simulation toolkit
journal, July 2003

  • Agostinelli, S.; Allison, J.; Amako, K.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 506, Issue 3
  • DOI: 10.1016/S0168-9002(03)01368-8

MULECS: The Monash University Low Energy Compton scattering package
conference, October 2011

  • Brown, J. M. C.; Dimmock, M. R.; Gillam, J. E.
  • 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference (2011 NSS/MIC), 2011 IEEE Nuclear Science Symposium Conference Record
  • DOI: 10.1109/NSSMIC.2011.6154623

A low energy bound atomic electron Compton scattering model for Geant4
journal, November 2014

  • Brown, J. M. C.; Dimmock, M. R.; Gillam, J. E.
  • Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, Vol. 338
  • DOI: 10.1016/j.nimb.2014.07.042

A general Monte Carlo simulation of energy-dispersive X-ray fluorescence spectrometers—I
journal, March 1993

  • Vincze, Laszlo; Janssen, Koen; Adams, Fred
  • Spectrochimica Acta Part B: Atomic Spectroscopy, Vol. 48, Issue 4
  • DOI: 10.1016/0584-8547(93)80060-8

A general Monte Carlo simulation of ED-XRF spectrometers. II: Polarized monochromatic radiation, homogeneous samples
journal, March 1995

  • Vincze, László; Janssens, Koen; Adams, Fred
  • Spectrochimica Acta Part B: Atomic Spectroscopy, Vol. 50, Issue 2
  • DOI: 10.1016/0584-8547(94)00124-E

A general Monte Carlo simulation of energy-dispersive X-ray fluorescence spectrometers. Part 3. Polarized polychromatic radiation, homogeneous samples
journal, October 1995

  • Vincze, László; Janssens, Koen; Adams, Fred
  • Spectrochimica Acta Part B: Atomic Spectroscopy, Vol. 50, Issue 12
  • DOI: 10.1016/0584-8547(95)01361-X

Monte Carlo simulation of X-ray fluorescence spectra: Part 4. Photon scattering at high X-ray energies
journal, November 1999


A general Monte Carlo simulation of energy dispersive X-ray fluorescence spectrometers — Part 5
journal, April 2012

  • Schoonjans, Tom; Vincze, Laszlo; Solé, Vicente Armando
  • Spectrochimica Acta Part B: Atomic Spectroscopy, Vol. 70
  • DOI: 10.1016/j.sab.2012.03.011

A general Monte Carlo simulation of energy-dispersive X-ray fluorescence spectrometers — Part 6. Quantification through iterative simulations
journal, April 2013

  • Schoonjans, Tom; Solé, Vicente Armando; Vincze, Laszlo
  • Spectrochimica Acta Part B: Atomic Spectroscopy, Vol. 82
  • DOI: 10.1016/j.sab.2012.12.011

Fast X-Ray Fluorescence Microtomography of Hydrated Biological Samples
journal, June 2011


Large detector array and real-time processing and elemental image projection of X-ray and proton microprobe fluorescence data
journal, July 2007

  • Ryan, C. G.; Siddons, D. P.; Moorhead, G.
  • Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, Vol. 260, Issue 1
  • DOI: 10.1016/j.nimb.2007.01.271

Elemental X-ray imaging using the Maia detector array: The benefits and challenges of large solid-angle
journal, July 2010

  • Ryan, C. G.; Kirkham, R.; Hough, R. M.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 619, Issue 1-3
  • DOI: 10.1016/j.nima.2009.11.035

Maia X-ray fluorescence imaging: Capturing detail in complex natural samples
journal, April 2014


Zinc availability regulates exit from meiosis in maturing mammalian oocytes
journal, August 2010

  • Kim, Alison M.; Vogt, Stefan; O'Halloran, Thomas V.
  • Nature Chemical Biology, Vol. 6, Issue 9
  • DOI: 10.1038/nchembio.419

The Scattering of Light by Free Electrons according to Dirac's New Relativistic Dynamics
journal, September 1928


Über die Streuung von Strahlung durch freie Elektronen nach der neuen relativistischen Quantendynamik von Dirac
journal, November 1929

  • Klein, O.; Nishina, Y.
  • Zeitschrift für Physik, Vol. 52, Issue 11-12
  • DOI: 10.1007/BF01366453

Atomic form factors, incoherent scattering functions, and photon scattering cross sections
journal, July 1975

  • Hubbell, J. H.; Veigele, Wm. J.; Briggs, E. A.
  • Journal of Physical and Chemical Reference Data, Vol. 4, Issue 3
  • DOI: 10.1063/1.555523

Sur l'effet photoélectrique composé
journal, January 1925


Atomic radiative and radiationless yields for K and L shells
journal, April 1979

  • Krause, M. O.
  • Journal of Physical and Chemical Reference Data, Vol. 8, Issue 2
  • DOI: 10.1063/1.555594

Potential operating region for ultrasoft x-ray microscopy of biological materials
journal, June 1977


A discussion of PIXAN and PIXANPC: The AAEC PIXE analysis computer packages
journal, March 1987

  • Clayton, E.; Duerden, P.; Cohen, David D.
  • Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, Vol. 22, Issue 1-3
  • DOI: 10.1016/0168-583X(87)90295-3

SNIP, a statistics-sensitive background treatment for the quantitative analysis of PIXE spectra in geoscience applications
journal, September 1988

  • Ryan, C. G.; Clayton, E.; Griffin, W. L.
  • Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, Vol. 34, Issue 3
  • DOI: 10.1016/0168-583X(88)90063-8

Quaternary structure of human fatty acid synthase by electron cryomicroscopy
journal, December 2001

  • Brink, J.; Ludtke, S. J.; Yang, C. -Y.
  • Proceedings of the National Academy of Sciences, Vol. 99, Issue 1
  • DOI: 10.1073/pnas.012589499

A method for forward energy-dispersive X-ray fluorescence analysis of thin and intermediate samples
journal, November 1998

  • Cesareo, Roberto; Gigante, Giovanni E.; Hanson, Albert L.
  • Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, Vol. 145, Issue 3
  • DOI: 10.1016/S0168-583X(98)00418-2

Monte Carlo simulation of X-ray imaging and spectroscopy experiments using quadric geometry and variance reduction techniques
journal, March 2014

  • Golosio, Bruno; Schoonjans, Tom; Brunetti, Antonio
  • Computer Physics Communications, Vol. 185, Issue 3
  • DOI: 10.1016/j.cpc.2013.10.034

The xraylib library for X-ray–matter interactions. Recent developments
journal, November 2011

  • Schoonjans, Tom; Brunetti, Antonio; Golosio, Bruno
  • Spectrochimica Acta Part B: Atomic Spectroscopy, Vol. 66, Issue 11-12
  • DOI: 10.1016/j.sab.2011.09.011

The theoretical derivation of fluorescent X-ray intensities from mixtures
journal, January 1955


Hard X-ray polarization measured with a Compton polarimeter at synchrotron radiation facility
journal, September 2004

  • Tokanai, F.; Sakurai, H.; Gunji, S.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 530, Issue 3
  • DOI: 10.1016/j.nima.2004.04.240

A method for selecting detector apertures for use in SRIXE
journal, October 1987

  • Hanson, A. L.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 260, Issue 1
  • DOI: 10.1016/0168-9002(87)90412-8

Works referencing / citing this record:

Optimization-based simultaneous alignment and reconstruction in multi-element tomography
journal, January 2019

  • Di, Zichao (Wendy); Chen, Si; Gursoy, Doga
  • Optics Letters, Vol. 44, Issue 17
  • DOI: 10.1364/ol.44.004331

Eliminating the non-Gaussian spectral response of X-ray absorbers for transition-edge sensors
journal, November 2017

  • Divan, Ralu; Gades, Lisa M.; Kenesei, Peter
  • Applied Physics Letters, Vol. 111, Issue 19
  • DOI: 10.1063/1.5001198

A high-throughput energy-dispersive tender X-ray spectrometer for shot-to-shot sulfur measurements
journal, April 2019

  • Abraham, Baxter; Nowak, Stanislaw; Weninger, Clemens
  • Journal of Synchrotron Radiation, Vol. 26, Issue 3
  • DOI: 10.1107/s1600577519002431

2016 Atomic Spectrometry Update – a review of advances in X-ray fluorescence spectrometry and its applications
journal, January 2016

  • West, Margaret; Ellis, Andrew T.; Potts, Philip J.
  • Journal of Analytical Atomic Spectrometry, Vol. 31, Issue 9
  • DOI: 10.1039/c6ja90034h

Incremental distribution of strontium and zinc in great ape and fossil hominin cementum using synchrotron X-ray fluorescence mapping
journal, January 2018

  • Dean, Christopher; Le Cabec, Adeline; Spiers, Kathryn
  • Journal of The Royal Society Interface, Vol. 15, Issue 138
  • DOI: 10.1098/rsif.2017.0626

Synchrotron hard X-ray chemical imaging of trace element speciation in heterogeneous samples: development of criteria for uncertainty analysis
journal, January 2020

  • Wielinski, Jonas; Marafatto, Francesco Femi; Gogos, Alexander
  • Journal of Analytical Atomic Spectrometry, Vol. 35, Issue 3
  • DOI: 10.1039/c9ja00394k

Effect of mechanical noise upon X-ray fluorescence analysis
journal, May 2019


Joint reconstruction of x-ray fluorescence and transmission tomography
journal, January 2017

  • Di, Zichao Wendy; Chen, Si; Hong, Young Pyo
  • Optics Express, Vol. 25, Issue 12
  • DOI: 10.1364/oe.25.013107

Incremental distribution of strontium and zinc in great ape and fossil hominin cementum using synchrotron X-ray fluorescence mapping
text, January 2018

  • Dean, Christopher; Le Cabec, Adeline; Spiers, Kathryn
  • Deutsches Elektronen-Synchrotron, DESY, Hamburg
  • DOI: 10.3204/pubdb-2018-00341

Fast X-ray microfluorescence imaging with submicrometer-resolution integrating a Maia detector at beamline P06 at PETRA III
text, January 2016

  • Boesenberg, Ulrike; Ryan, Christopher G.; Kirkham, Robin
  • Deutsches Elektronen-Synchrotron, DESY, Hamburg
  • DOI: 10.3204/pubdb-2016-04604