DOE PAGES title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Simulation of High-Resolution Magnetic Resonance Images on the IBM Blue Gene/L Supercomputer Using SIMRI

Journal Article · · International Journal of Biomedical Imaging
 [1];  [1];  [1]
  1. Chester F. Carlson Center for Imaging Science, Rochester Institute of Technology, 54 Lomb Memorial Drive, Rochester, NY 14623, USA

Medical imaging system simulators are tools that provide a means to evaluate system architecture and create artificial image sets that are appropriate for specific applications. We have modified SIMRI, a Bloch equation-based magnetic resonance image simulator, in order to successfully generate high-resolution 3D MR images of the Montreal brain phantom using Blue Gene/L systems. Results show that redistribution of the workload allows an anatomically accurate 256 3 voxel spin-echo simulation in less than 5 hours when executed on an 8192-node partition of a Blue Gene/L system.

Sponsoring Organization:
USDOE
Grant/Contract Number:
AC02-98CH10886
OSTI ID:
1198452
Journal Information:
International Journal of Biomedical Imaging, Journal Name: International Journal of Biomedical Imaging Vol. 2011; ISSN 1687-4188
Publisher:
Hindawi Publishing CorporationCopyright Statement
Country of Publication:
United Kingdom
Language:
English

References (16)

Direct simulation of spin echoes by summation of isochromats journal January 1996
Simulation of in-plane flow imaging journal January 1999
A computer simulation program for mr imaging: application to rf and static magnetic field imperfections journal October 1995
A computer algorithm for the simulation of any Nuclear Magnetic Resonance (NMR) imaging method journal January 1984
MRI simulation using the k-space formalism journal January 1993
Simulation of MRI cluster plots and application to neurological segmentation journal January 1996
The SIMRI project: a versatile and interactive MRI simulator journal March 2005
Efficient simulation of magnetic resonance imaging with Bloch–Torrey equations using intra-voxel magnetization gradients journal May 2006
MRI simulator with object-specific field map calculations journal April 2004
A new improved version of the realistic digital brain phantom journal August 2006
Nuclear Induction journal October 1946
Spin Echoes journal November 1950
Design and construction of a realistic digital brain phantom journal June 1998
MRI simulation-based evaluation of image-processing and classification methods journal January 1999
Twenty New Digital Brain Phantoms for Creation of Validation Image Data Bases journal November 2006
Analytical tools for magnetic resonance imaging. journal November 1984

Similar Records

High resolution, MRI-based, segmented, computerized head phantom
Conference · Thu Dec 31 23:00:00 EST 1998 · OSTI ID:684487

SU-E-I-60: Quality Assurance Testing Methods and Customized Phantom for Magnetic Resonance Imaging and Spectroscopy
Journal Article · Mon Jun 15 00:00:00 EDT 2015 · Medical Physics · OSTI ID:22494012

Massively-parallel electrical-conductivity imaging of hydrocarbonsusing the Blue Gene/L supercomputer
Journal Article · Wed May 16 00:00:00 EDT 2007 · IBM Journal of Research and Development · OSTI ID:932690

Related Subjects