Title: Prediction of performance for a fire-tube boiler with and without turbulators

Technical Report ·
OSTI ID:5782217

A series of computer runs were made using DEPAB2 (the boiler simulation computer program). They include the runs for a fire-tube boiler as is (i.e., without turbulators), with wire-coil type turbulators, and with twisted-tape type turbulators, respectively. Output from these runs are used to evaluate the boiler seasonal performance values under the Washington, D.C. weather conditions. Results show that the turbulator increases the boiler seasonal efficiency from 2.87 to 6.08%.

Research Organization:
National Engineering Lab. (NBS), Washington, DC (USA)
OSTI ID:
5782217
Report Number(s):
PB-85-177871/XAB; NBSIR-84/2925
Resource Relation:
Other Information: Sponsored by Army Facilities Engineering Support Agency, Fort Belvoir, VA, Technology Support Div
Country of Publication:
United States
Language:
English