DOE Data Explorer title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: SCILLA nitrogen oxide (NOx) airborne data

Abstract

Nitrogen oxides mixing ratios in ppb are measured using a Teledyne API Model T200UP.  The analyzer uses chemiluminescence to determine NO concentration.  Alternating measurement of the concentrations of total NOx (NO + NO2) and just NO are made by directing the sample through a blue light converter that photolyzes NO2 to NO and bypassing it, respectively, with the NO2 concentration calculated as the difference between the two.  Sampled air was pulled from above the Naval Postgraduate School’s (NPS) Twin Otter aircraft through a rear-facing, ¼” OD PFA Teflon tube. The sample stream was split between several other gas analyzers (CO, O3, and H2O) and an oxidation flow reactor. The NO, NO2, and NOx mixing ratios were recorded once per minute.

Authors:
ORCiD logo ; ; ORCiD logo ; ORCiD logo
Publication Date:
DOE Contract Number:  
AC05-00OR22725
Research Org.:
Atmospheric Radiation Measurement User Facility
Sponsoring Org.:
USDOE Office of Science (SC), Biological and Environmental Research (BER)
Collaborations:
PNNL, BNL, ANL, ORNL
Subject:
NOx concentration; troposphere
OSTI Identifier:
2572200
DOI:
https://doi.org/10.5439/2572200

Citation Formats

Collins, Don, Han, Minghao, Witte, Mikael, and Bucholtz, Anthony. SCILLA nitrogen oxide (NOx) airborne data. United States: N. p., 2025. Web. doi:10.5439/2572200.
Collins, Don, Han, Minghao, Witte, Mikael, & Bucholtz, Anthony. SCILLA nitrogen oxide (NOx) airborne data. United States. doi:https://doi.org/10.5439/2572200
Collins, Don, Han, Minghao, Witte, Mikael, and Bucholtz, Anthony. 2025. "SCILLA nitrogen oxide (NOx) airborne data". United States. doi:https://doi.org/10.5439/2572200. https://www.osti.gov/servlets/purl/2572200. Pub date:Thu Jul 17 00:00:00 EDT 2025
@article{osti_2572200,
title = {SCILLA nitrogen oxide (NOx) airborne data},
author = {Collins, Don and Han, Minghao and Witte, Mikael and Bucholtz, Anthony},
abstractNote = {Nitrogen oxides mixing ratios in ppb are measured using a Teledyne API Model T200UP.  The analyzer uses chemiluminescence to determine NO concentration.  Alternating measurement of the concentrations of total NOx (NO + NO2) and just NO are made by directing the sample through a blue light converter that photolyzes NO2 to NO and bypassing it, respectively, with the NO2 concentration calculated as the difference between the two.  Sampled air was pulled from above the Naval Postgraduate School’s (NPS) Twin Otter aircraft through a rear-facing, ¼” OD PFA Teflon tube. The sample stream was split between several other gas analyzers (CO, O3, and H2O) and an oxidation flow reactor. The NO, NO2, and NOx mixing ratios were recorded once per minute.},
doi = {10.5439/2572200},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Thu Jul 17 00:00:00 EDT 2025},
month = {Thu Jul 17 00:00:00 EDT 2025}
}