SCILLA nitrogen oxide (NOx) airborne data
Abstract
Nitrogen oxides mixing ratios in ppb are measured using a Teledyne API Model T200UP. The analyzer uses chemiluminescence to determine NO concentration. Alternating measurement of the concentrations of total NOx (NO + NO2) and just NO are made by directing the sample through a blue light converter that photolyzes NO2 to NO and bypassing it, respectively, with the NO2 concentration calculated as the difference between the two. Sampled air was pulled from above the Naval Postgraduate School’s (NPS) Twin Otter aircraft through a rear-facing, ¼” OD PFA Teflon tube. The sample stream was split between several other gas analyzers (CO, O3, and H2O) and an oxidation flow reactor. The NO, NO2, and NOx mixing ratios were recorded once per minute.
- Authors:
- Publication Date:
- DOE Contract Number:
- AC05-00OR22725
- Research Org.:
- Atmospheric Radiation Measurement User Facility
- Sponsoring Org.:
- USDOE Office of Science (SC), Biological and Environmental Research (BER)
- Collaborations:
- PNNL, BNL, ANL, ORNL
- Subject:
- NOx concentration; troposphere
- OSTI Identifier:
- 2572200
- DOI:
- https://doi.org/10.5439/2572200
Citation Formats
Collins, Don, Han, Minghao, Witte, Mikael, and Bucholtz, Anthony. SCILLA nitrogen oxide (NOx) airborne data. United States: N. p., 2025.
Web. doi:10.5439/2572200.
Collins, Don, Han, Minghao, Witte, Mikael, & Bucholtz, Anthony. SCILLA nitrogen oxide (NOx) airborne data. United States. doi:https://doi.org/10.5439/2572200
Collins, Don, Han, Minghao, Witte, Mikael, and Bucholtz, Anthony. 2025.
"SCILLA nitrogen oxide (NOx) airborne data". United States. doi:https://doi.org/10.5439/2572200. https://www.osti.gov/servlets/purl/2572200. Pub date:Thu Jul 17 00:00:00 EDT 2025
@article{osti_2572200,
title = {SCILLA nitrogen oxide (NOx) airborne data},
author = {Collins, Don and Han, Minghao and Witte, Mikael and Bucholtz, Anthony},
abstractNote = {Nitrogen oxides mixing ratios in ppb are measured using a Teledyne API Model T200UP. The analyzer uses chemiluminescence to determine NO concentration. Alternating measurement of the concentrations of total NOx (NO + NO2) and just NO are made by directing the sample through a blue light converter that photolyzes NO2 to NO and bypassing it, respectively, with the NO2 concentration calculated as the difference between the two. Sampled air was pulled from above the Naval Postgraduate School’s (NPS) Twin Otter aircraft through a rear-facing, ¼” OD PFA Teflon tube. The sample stream was split between several other gas analyzers (CO, O3, and H2O) and an oxidation flow reactor. The NO, NO2, and NOx mixing ratios were recorded once per minute.},
doi = {10.5439/2572200},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Thu Jul 17 00:00:00 EDT 2025},
month = {Thu Jul 17 00:00:00 EDT 2025}
}