Orbitrap LC-MS Analysis of Nanoparticle Composition at the EPCAPE Mount Soledad site between 04 18 2023 and 06 14 2023
Abstract
Weekly peak lists containing m/z, intensity, and assigned formula for filter samples, size selected for sub-100 nm particles. Filters were collected daily between 4/18/23 and 6/14/23, grouped based on calendar week for extraction, and analyzed via Thermo Scientific Q Exactive Plus Orbitrap LC-MS. Formulas were assigned to background-corrected peak lists and restricted to CHONS/CHONSNa atoms for the negative and positive modes respectively. Filters were grouped into calendar weeks 0-8 with dates provided in README text file.
- Authors:
-
- ORNL
- Publication Date:
- Other Number(s):
- ARM0838
- DOE Contract Number:
- AC05-00OR22725
- Research Org.:
- Atmospheric Radiation Measurement (ARM) Archive, Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (US); ARM Data Center, Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
- Sponsoring Org.:
- USDOE Office of Science (SC), Biological and Environmental Research (BER)
- Collaborations:
- PNNL, BNL, ANL, ORNL
- Subject:
- 54 ENVIRONMENTAL SCIENCES
- OSTI Identifier:
- 2352651
- DOI:
- https://doi.org/10.5439/2352651
Citation Formats
Cramer, Kristen. Orbitrap LC-MS Analysis of Nanoparticle Composition at the EPCAPE Mount Soledad site between 04 18 2023 and 06 14 2023. United States: N. p., 2024.
Web. doi:10.5439/2352651.
Cramer, Kristen. Orbitrap LC-MS Analysis of Nanoparticle Composition at the EPCAPE Mount Soledad site between 04 18 2023 and 06 14 2023. United States. doi:https://doi.org/10.5439/2352651
Cramer, Kristen. 2024.
"Orbitrap LC-MS Analysis of Nanoparticle Composition at the EPCAPE Mount Soledad site between 04 18 2023 and 06 14 2023". United States. doi:https://doi.org/10.5439/2352651. https://www.osti.gov/servlets/purl/2352651. Pub date:Wed May 22 00:00:00 EDT 2024
@article{osti_2352651,
title = {Orbitrap LC-MS Analysis of Nanoparticle Composition at the EPCAPE Mount Soledad site between 04 18 2023 and 06 14 2023},
author = {Cramer, Kristen},
abstractNote = {Weekly peak lists containing m/z, intensity, and assigned formula for filter samples, size selected for sub-100 nm particles. Filters were collected daily between 4/18/23 and 6/14/23, grouped based on calendar week for extraction, and analyzed via Thermo Scientific Q Exactive Plus Orbitrap LC-MS. Formulas were assigned to background-corrected peak lists and restricted to CHONS/CHONSNa atoms for the negative and positive modes respectively. Filters were grouped into calendar weeks 0-8 with dates provided in README text file.},
doi = {10.5439/2352651},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Wed May 22 00:00:00 EDT 2024},
month = {Wed May 22 00:00:00 EDT 2024}
}
Save to My Library
You must Sign In or Create an Account in order to save documents to your library.
