Strain glass state of magnetic shape memory alloy Ni45Co5Mn36.6In13.4 measured on SEQUOIA at 5 K
Abstract
Combined inelastic neutron scattering data from SEQUOIA on the strain glass state of Ni45Co5Mn36.6In13.4 measured at 5 K. Crystal was oriented with HHL in the scattering plane. To obtain a large Q-E volume the crystal was rotated in the beam and the individual angles were combined using the HORACE software package (https://pace-neutrons.github.io/Horace/unstable/user_guide/Getting_started.html).
- Authors:
-
- Oak Ridge National Laboratory
- Publication Date:
- Other Number(s):
- 660f2491dab1a56143155c62
IPTS-17106
- DOE Contract Number:
- AC05-00OR22725
- Research Org.:
- High Flux Isotope Reactor (HFIR) & Spallation Neutron Source (SNS), Oak Ridge National Laboratory (ORNL); Spallation Neutron Source (SNS)
- Sponsoring Org.:
- USDOE Office of Science (SC), Basic Energy Sciences (BES)
- Subject:
- MATERIALS SCIENCE; excitations
- OSTI Identifier:
- 2335305
- DOI:
- https://doi.org/10.14461/oncat.data/2335305
Citation Formats
Manley, Michael, Stonaha, Paul, and Stone, Matthew. Strain glass state of magnetic shape memory alloy Ni45Co5Mn36.6In13.4 measured on SEQUOIA at 5 K. United States: N. p., 2024.
Web. doi:10.14461/oncat.data/2335305.
Manley, Michael, Stonaha, Paul, & Stone, Matthew. Strain glass state of magnetic shape memory alloy Ni45Co5Mn36.6In13.4 measured on SEQUOIA at 5 K. United States. doi:https://doi.org/10.14461/oncat.data/2335305
Manley, Michael, Stonaha, Paul, and Stone, Matthew. 2024.
"Strain glass state of magnetic shape memory alloy Ni45Co5Mn36.6In13.4 measured on SEQUOIA at 5 K". United States. doi:https://doi.org/10.14461/oncat.data/2335305. https://www.osti.gov/servlets/purl/2335305. Pub date:Mon Apr 08 00:00:00 EDT 2024
@article{osti_2335305,
title = {Strain glass state of magnetic shape memory alloy Ni45Co5Mn36.6In13.4 measured on SEQUOIA at 5 K},
author = {Manley, Michael and Stonaha, Paul and Stone, Matthew},
abstractNote = {Combined inelastic neutron scattering data from SEQUOIA on the strain glass state of Ni45Co5Mn36.6In13.4 measured at 5 K. Crystal was oriented with HHL in the scattering plane. To obtain a large Q-E volume the crystal was rotated in the beam and the individual angles were combined using the HORACE software package (https://pace-neutrons.github.io/Horace/unstable/user_guide/Getting_started.html).},
doi = {10.14461/oncat.data/2335305},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Mon Apr 08 00:00:00 EDT 2024},
month = {Mon Apr 08 00:00:00 EDT 2024}
}
Save to My Library