DOE Data Explorer title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Brookfield Homes Passive House Performance Evaluation

Abstract

TO4 3.1.3: Brookfield Homes Short-Term Results TO5 3.1.3: Brookfield Passive House Monitoring To further define its market position on high performance homebuilding, Brookfield worked with IBACOS and the Building America program to design and construct a Passive House (PH) certified model home in Denver, CO to evaluate advanced building technologies and to use as a marketing tool for potential homebuyers. Brookfield used a new architect and a new floor plan as a standard production model and constructed it to the PH standard as an upgrade option. This PH was completely built and certified in August 2013.

Authors:
; ;
  1. Ibacos Innovation
Publication Date:
Other Number(s):
5126
Research Org.:
DOE Open Energy Data Initiative (OEDI); Ibacos Innovation
Sponsoring Org.:
USDOE Office of Energy Efficiency and Renewable Energy (EERE), Multiple Programs (EE)
Collaborations:
Ibacos Innovation
Subject:
Array; BuildingAmerica; HVAC; Passive house; Passive house planning package; beopt; building america; cold; comfort; community; energy recovery ventilator; new construction; residential; single family detached; technical drawings; ventilation; zero energy ready home
OSTI Identifier:
2204249
DOI:
https://doi.org/10.25984/2204249

Citation Formats

Beach, Robert, Herk, Anastasia, and Poerschke, Andrew. Brookfield Homes Passive House Performance Evaluation. United States: N. p., 2016. Web. doi:10.25984/2204249.
Beach, Robert, Herk, Anastasia, & Poerschke, Andrew. Brookfield Homes Passive House Performance Evaluation. United States. doi:https://doi.org/10.25984/2204249
Beach, Robert, Herk, Anastasia, and Poerschke, Andrew. 2016. "Brookfield Homes Passive House Performance Evaluation". United States. doi:https://doi.org/10.25984/2204249. https://www.osti.gov/servlets/purl/2204249. Pub date:Wed Apr 27 00:00:00 EDT 2016
@article{osti_2204249,
title = {Brookfield Homes Passive House Performance Evaluation},
author = {Beach, Robert and Herk, Anastasia and Poerschke, Andrew},
abstractNote = {TO4 3.1.3: Brookfield Homes Short-Term Results TO5 3.1.3: Brookfield Passive House Monitoring To further define its market position on high performance homebuilding, Brookfield worked with IBACOS and the Building America program to design and construct a Passive House (PH) certified model home in Denver, CO to evaluate advanced building technologies and to use as a marketing tool for potential homebuyers. Brookfield used a new architect and a new floor plan as a standard production model and constructed it to the PH standard as an upgrade option. This PH was completely built and certified in August 2013.},
doi = {10.25984/2204249},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Wed Apr 27 00:00:00 EDT 2016},
month = {Wed Apr 27 00:00:00 EDT 2016}
}