High-energy inelastic neutron scattering data taken at the SEQUOIA spectrometer.
Abstract
INS measurements were performed using the Fine Resolution Chopper Spectrometer SEQUOIA at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. A powder sample of SrCoGe2O6 was loaded in an aluminum can for the measurements and a CCR was used to cool the sample down to 6 K. Data were collected using fixed incident neutron energies of 100 and 30 meV.
- Authors:
-
- Oak Ridge National Laboratory
- Publication Date:
- Other Number(s):
- 64d649ab9a4f9cddec92b19a
IPTS-31247
- DOE Contract Number:
- AC05-00OR22725
- Research Org.:
- High Flux Isotope Reactor (HFIR) & Spallation Neutron Source (SNS), Oak Ridge National Laboratory (ORNL); Spallation Neutron Source (SNS)
- Sponsoring Org.:
- USDOE Office of Science (SC), Basic Energy Sciences (BES)
- Subject:
- MATERIALS SCIENCE
- OSTI Identifier:
- 2204020
- DOI:
- https://doi.org/10.14461/oncat.data.64d649ab9a4f9cddec92b19a/2204020
Citation Formats
Kolesnikov, Alexander, and Podlesnyak, Andrey. High-energy inelastic neutron scattering data taken at the SEQUOIA spectrometer.. United States: N. p., 2023.
Web. doi:10.14461/oncat.data.64d649ab9a4f9cddec92b19a/2204020.
Kolesnikov, Alexander, & Podlesnyak, Andrey. High-energy inelastic neutron scattering data taken at the SEQUOIA spectrometer.. United States. doi:https://doi.org/10.14461/oncat.data.64d649ab9a4f9cddec92b19a/2204020
Kolesnikov, Alexander, and Podlesnyak, Andrey. 2023.
"High-energy inelastic neutron scattering data taken at the SEQUOIA spectrometer.". United States. doi:https://doi.org/10.14461/oncat.data.64d649ab9a4f9cddec92b19a/2204020. https://www.osti.gov/servlets/purl/2204020. Pub date:Tue Oct 31 00:00:00 EDT 2023
@article{osti_2204020,
title = {High-energy inelastic neutron scattering data taken at the SEQUOIA spectrometer.},
author = {Kolesnikov, Alexander and Podlesnyak, Andrey},
abstractNote = {INS measurements were performed using the Fine Resolution Chopper Spectrometer SEQUOIA at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. A powder sample of SrCoGe2O6 was loaded in an aluminum can for the measurements and a CCR was used to cool the sample down to 6 K. Data were collected using fixed incident neutron energies of 100 and 30 meV.},
doi = {10.14461/oncat.data.64d649ab9a4f9cddec92b19a/2204020},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Tue Oct 31 00:00:00 EDT 2023},
month = {Tue Oct 31 00:00:00 EDT 2023}
}
Save to My Library
You must Sign In or Create an Account in order to save documents to your library.
