PW2 Pumping: March 18 thru March 22, 2020
Abstract
Processed Coherence-length-gated Microwave Photonics Interferometry (CMPI) distributed vertical strain on March 18 through March 22, 2020 at the hydromechanical test facility located at the Clemson University Simpson Station research facility in Central, South Carolina, USA. This includes ambient data in addition to a pumping test performed between 14:31-20:31 EST on 3/22/2020 from Pumping Well 2 (PW2). These data are from a strain ribbon that was deployed in the vadose zone at approximately 34.670130°N, -82.729524°E from the ground surface to a depth of 8m in saprolite containing weak reflectors pairs were placed every 0.85 m along the fiber. Each weak reflector pair forms a 15 cm cavity strain meter. Strain unit: meters/meter (strain). Sampling rate 0.1 Hz. Each column corresponds to the strain data taken at a depth d from the ground surface. c1: d = 1.00m c2: d = 1.85m c3: d = 2.70m c4: d = 3.55m (large demodulation error) c5: d = 4.40m c6: d = 5.25m c7: d = 6.10m (large demodulation error) c8: d = 6.95m
- Authors:
-
- Clemson University
- Publication Date:
- Other Number(s):
- 31492cd8-c5d4-46e1-8d8e-d13effcd1048
- DOE Contract Number:
- FE0028292
- Research Org.:
- National Energy Technology Laboratory - Energy Data eXchange; NETL
- Sponsoring Org.:
- USDOE Office of Fossil Energy (FE)
- Subject:
- Distributed Strain Sensing; Optical fiber sensors; Well Test Data
- OSTI Identifier:
- 2006987
- DOI:
- https://doi.org/10.18141/2006987
Citation Formats
DeWolf, Scott, Hua, Liwei, Murdoch, Lawrence C, and Blais, Riley. PW2 Pumping: March 18 thru March 22, 2020. United States: N. p., 2023.
Web. doi:10.18141/2006987.
DeWolf, Scott, Hua, Liwei, Murdoch, Lawrence C, & Blais, Riley. PW2 Pumping: March 18 thru March 22, 2020. United States. doi:https://doi.org/10.18141/2006987
DeWolf, Scott, Hua, Liwei, Murdoch, Lawrence C, and Blais, Riley. 2023.
"PW2 Pumping: March 18 thru March 22, 2020". United States. doi:https://doi.org/10.18141/2006987. https://www.osti.gov/servlets/purl/2006987. Pub date:Mon Oct 02 04:00:00 UTC 2023
@article{osti_2006987,
title = {PW2 Pumping: March 18 thru March 22, 2020},
author = {DeWolf, Scott and Hua, Liwei and Murdoch, Lawrence C and Blais, Riley},
abstractNote = {Processed Coherence-length-gated Microwave Photonics Interferometry (CMPI) distributed vertical strain on March 18 through March 22, 2020 at the hydromechanical test facility located at the Clemson University Simpson Station research facility in Central, South Carolina, USA. This includes ambient data in addition to a pumping test performed between 14:31-20:31 EST on 3/22/2020 from Pumping Well 2 (PW2). These data are from a strain ribbon that was deployed in the vadose zone at approximately 34.670130°N, -82.729524°E from the ground surface to a depth of 8m in saprolite containing weak reflectors pairs were placed every 0.85 m along the fiber. Each weak reflector pair forms a 15 cm cavity strain meter. Strain unit: meters/meter (strain). Sampling rate 0.1 Hz. Each column corresponds to the strain data taken at a depth d from the ground surface. c1: d = 1.00m c2: d = 1.85m c3: d = 2.70m c4: d = 3.55m (large demodulation error) c5: d = 4.40m c6: d = 5.25m c7: d = 6.10m (large demodulation error) c8: d = 6.95m},
doi = {10.18141/2006987},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Mon Oct 02 04:00:00 UTC 2023},
month = {Mon Oct 02 04:00:00 UTC 2023}
}