Low-field-orientation effect on REBCO tape performance and its power cable application
Abstract
Low field characteristics, including field orientation dependence relations for four different commercially available REBCO tapes, were investigated in an external field of up to 0.3 T at 77 K. A design method of the performance of a twisted stacked-tape conductor (TSTC) has been developed for a power transmission line. Cable critical current is obtained from an averaged self-field distributed over the cable cross section and the minimum critical current obtained from the field orientation dependence in transverse fields experimentally measured for the single tapes. The performance of three types of TSTCs, i.e., single-, double-, and triple-channel configurations, has been assessed for the four REBCO tapes.
- Authors:
-
- OSTI
- Publication Date:
- DOE Contract Number:
- FC02-93ER54186; SC0004062; SC0004269
- Research Org.:
- Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States). Plasma Science and Fusion Center; Tufts Univ., Medford, MA (United States); Supercon, Inc., Shrewsbury, MA (United States)
- Sponsoring Org.:
- USDOE Office of Science (SC), Fusion Energy Sciences (FES); USDOE Office of Science (SC), Engineering & Technology. Office of Small Business Innovation Research (SBIR) and Small Business Technology Transfer (STTR) Programs
- Subject:
- 75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND SUPERFLUIDITY
- OSTI Identifier:
- 1882838
- DOI:
- https://doi.org/10.7910/DVN/WKEWUX
Citation Formats
Takayasu, Makoto, Chiesa, Luisa, and Minervini, Joseph V. Low-field-orientation effect on REBCO tape performance and its power cable application. United States: N. p., 2021.
Web. doi:10.7910/DVN/WKEWUX.
Takayasu, Makoto, Chiesa, Luisa, & Minervini, Joseph V. Low-field-orientation effect on REBCO tape performance and its power cable application. United States. doi:https://doi.org/10.7910/DVN/WKEWUX
Takayasu, Makoto, Chiesa, Luisa, and Minervini, Joseph V. 2021.
"Low-field-orientation effect on REBCO tape performance and its power cable application". United States. doi:https://doi.org/10.7910/DVN/WKEWUX. https://www.osti.gov/servlets/purl/1882838. Pub date:Wed Jun 23 00:00:00 EDT 2021
@article{osti_1882838,
title = {Low-field-orientation effect on REBCO tape performance and its power cable application},
author = {Takayasu, Makoto and Chiesa, Luisa and Minervini, Joseph V.},
abstractNote = {Low field characteristics, including field orientation dependence relations for four different commercially available REBCO tapes, were investigated in an external field of up to 0.3 T at 77 K. A design method of the performance of a twisted stacked-tape conductor (TSTC) has been developed for a power transmission line. Cable critical current is obtained from an averaged self-field distributed over the cable cross section and the minimum critical current obtained from the field orientation dependence in transverse fields experimentally measured for the single tapes. The performance of three types of TSTCs, i.e., single-, double-, and triple-channel configurations, has been assessed for the four REBCO tapes.},
doi = {10.7910/DVN/WKEWUX},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Wed Jun 23 00:00:00 EDT 2021},
month = {Wed Jun 23 00:00:00 EDT 2021}
}
Save to My Library