Computed Tomography Scans of Naturally Mineralized Fractures in Upper Wolfcamp Shale
Abstract
Computed tomography scans of fractures in small samples of Wolfcamp Shale from the Permian Basin and a depth of approximately 10,400 feet that have been cemented through natural processes. These samples were CT scanned at NETL. The data sets compliment the manuscript by Hajirezaie et al entitled "Mineral characterization of a sealed fracture: A multiscale multimodal imaging study of a syntaxial vein"
- Authors:
-
- National Energy Technology Laboratory
- Publication Date:
- Other Number(s):
- 6a099686-9ce0-4fc9-b170-d8d6f1c5b1b9
- Research Org.:
- National Energy Technology Laboratory - Energy Data eXchange; NETL
- Sponsoring Org.:
- USDOE Office of Fossil Energy (FE)
- Subject:
- Computed Tomography; Fracture; Mineralization and Cements; Wolfcamp; shale
- OSTI Identifier:
- 1827827
- DOI:
- https://doi.org/10.18141/1827827
Citation Formats
Crandall, Dustin, Peters, Catherine, and Hajirezaie, Sassan. Computed Tomography Scans of Naturally Mineralized Fractures in Upper Wolfcamp Shale. United States: N. p., 2021.
Web. doi:10.18141/1827827.
Crandall, Dustin, Peters, Catherine, & Hajirezaie, Sassan. Computed Tomography Scans of Naturally Mineralized Fractures in Upper Wolfcamp Shale. United States. doi:https://doi.org/10.18141/1827827
Crandall, Dustin, Peters, Catherine, and Hajirezaie, Sassan. 2021.
"Computed Tomography Scans of Naturally Mineralized Fractures in Upper Wolfcamp Shale". United States. doi:https://doi.org/10.18141/1827827. https://www.osti.gov/servlets/purl/1827827. Pub date:Sat Oct 30 04:00:00 UTC 2021
@article{osti_1827827,
title = {Computed Tomography Scans of Naturally Mineralized Fractures in Upper Wolfcamp Shale},
author = {Crandall, Dustin and Peters, Catherine and Hajirezaie, Sassan},
abstractNote = {Computed tomography scans of fractures in small samples of Wolfcamp Shale from the Permian Basin and a depth of approximately 10,400 feet that have been cemented through natural processes. These samples were CT scanned at NETL. The data sets compliment the manuscript by Hajirezaie et al entitled "Mineral characterization of a sealed fracture: A multiscale multimodal imaging study of a syntaxial vein"},
doi = {10.18141/1827827},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Sat Oct 30 04:00:00 UTC 2021},
month = {Sat Oct 30 04:00:00 UTC 2021}
}
Save to My Library