REopt Lite Geothermal Heat Pump Design Requirements
Abstract
This document describes the design requirements for the geothermal heat pump (GHP) module being added to the existing REopt Lite web tool. This document describes the purpose, users, and functional requirements to which the modified web tool shall conform. This document will be revised, as required, throughout the development phase with consensus between the Department of Energy (DOE) Geothermal Technologies Office (GTO) and NREL. The GHP module will expand existing REopt Lite capabilities to include techno-economic optimization of GHP systems, either stand alone, or integrated with the other existing technology types, namely solar photovoltaics (PV), wind power, battery energy storage, thermal energy storage, combined hear and power (CHP), and absorption chiller. Included in this submission are links to the REopt Lite web tool, API, and open-source Git-Hub page. The REopt Lite tool can also be accessed directly via the NREL Developer Network. A link is also provided for the REopt report that overviews the module's capabilities.
- Authors:
- Publication Date:
- Other Number(s):
- 1293
- DOE Contract Number:
- FY21 AOP 4.6.2.13
- Research Org.:
- USDOE Geothermal Data Repository (United States); National Renewable Energy Lab. (NREL), Golden, CO (United States)
- Sponsoring Org.:
- USDOE Office of Energy Efficiency and Renewable Energy (EERE), Renewable Power Office. Geothermal Technologies Program (EE-4G)
- Collaborations:
- National Renewable Energy Laboratory
- Subject:
- 15 Geothermal Energy
- Keywords:
- geothermal; energy; REopt; REopt Lite; GHP; Geothermal Heat Pump; model; module; web tool; web interface; tool; techno-economic; economics
- Geolocation:
- 83.0,180.0|-83.0,180.0|-83.0,-180.0|83.0,-180.0|83.0,180.0
- OSTI Identifier:
- 1798194
- DOI:
- https://doi.org/10.15121/1798194
- Project Location:
-
Citation Formats
Anderson, Kate. REopt Lite Geothermal Heat Pump Design Requirements. United States: N. p., 2021.
Web. doi:10.15121/1798194.
Anderson, Kate. REopt Lite Geothermal Heat Pump Design Requirements. United States. doi:https://doi.org/10.15121/1798194
Anderson, Kate. 2021.
"REopt Lite Geothermal Heat Pump Design Requirements". United States. doi:https://doi.org/10.15121/1798194. https://www.osti.gov/servlets/purl/1798194. Pub date:Mon Mar 08 00:00:00 EST 2021
@article{osti_1798194,
title = {REopt Lite Geothermal Heat Pump Design Requirements},
author = {Anderson, Kate},
abstractNote = {This document describes the design requirements for the geothermal heat pump (GHP) module being added to the existing REopt Lite web tool. This document describes the purpose, users, and functional requirements to which the modified web tool shall conform. This document will be revised, as required, throughout the development phase with consensus between the Department of Energy (DOE) Geothermal Technologies Office (GTO) and NREL. The GHP module will expand existing REopt Lite capabilities to include techno-economic optimization of GHP systems, either stand alone, or integrated with the other existing technology types, namely solar photovoltaics (PV), wind power, battery energy storage, thermal energy storage, combined hear and power (CHP), and absorption chiller. Included in this submission are links to the REopt Lite web tool, API, and open-source Git-Hub page. The REopt Lite tool can also be accessed directly via the NREL Developer Network. A link is also provided for the REopt report that overviews the module's capabilities.},
doi = {10.15121/1798194},
journal = {},
number = ,
volume = ,
place = {United States},
year = {2021},
month = {3}
}