WCM water content for ACE-ENA
Abstract
The WCM-2000, manufactured by Science Engineering Associates (SEA), is a multi-element water content measuring system that measures both liquid water content (LWC) and total water content (TWC), allowing the inference of ice water content (IWC). The TWC is measured by a scoop-shaped sensor that collects both liquid and ice phase hydrometeors. The WCM-2000 also has two heated wire elements that are exposed directly to the airstream and a reference or compensation element that is exposed to the airflow but not the condensed water. The two heated wires measure the LWC for different size droplets and are sized to match the Johnson-Williams (JW) (021 Wire) LWC probe (0.5 mm; Neel 1955) and the King (083 Wire) probe (2 mm; King et al. 1978). The WCM-2000 is calibrated according to the manufacturer instructions, which involve a dedicated test flight in cloud-free air. Each flight is also corrected for zero-offset bias using clear-air measurements
- Authors:
-
- ORNL
- Publication Date:
- DOE Contract Number:
- AC05-00OR22725
- Research Org.:
- Atmospheric Radiation Measurement (ARM) Archive, Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (US); ARM Data Center, Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
- Sponsoring Org.:
- USDOE Office of Science (SC), Biological and Environmental Research (BER)
- Collaborations:
- PNL, BNL,ANL,ORNL
- Subject:
- 54 ENVIRONMENTAL SCIENCES; WCM-2000, liquid water content (LWC), total water content (TWC), ice water content (IWC), ACE-ENA, ARM, DOE
- OSTI Identifier:
- 1465759
- DOI:
- https://doi.org/10.5439/1465759
Citation Formats
Matthews, Alyssa, and Mei, Fan. WCM water content for ACE-ENA. United States: N. p., 2017.
Web. doi:10.5439/1465759.
Matthews, Alyssa, & Mei, Fan. WCM water content for ACE-ENA. United States. doi:https://doi.org/10.5439/1465759
Matthews, Alyssa, and Mei, Fan. 2017.
"WCM water content for ACE-ENA". United States. doi:https://doi.org/10.5439/1465759. https://www.osti.gov/servlets/purl/1465759. Pub date:Wed Jun 21 04:00:00 UTC 2017
@article{osti_1465759,
title = {WCM water content for ACE-ENA},
author = {Matthews, Alyssa and Mei, Fan},
abstractNote = {The WCM-2000, manufactured by Science Engineering Associates (SEA), is a multi-element water content measuring system that measures both liquid water content (LWC) and total water content (TWC), allowing the inference of ice water content (IWC). The TWC is measured by a scoop-shaped sensor that collects both liquid and ice phase hydrometeors. The WCM-2000 also has two heated wire elements that are exposed directly to the airstream and a reference or compensation element that is exposed to the airflow but not the condensed water. The two heated wires measure the LWC for different size droplets and are sized to match the Johnson-Williams (JW) (021 Wire) LWC probe (0.5 mm; Neel 1955) and the King (083 Wire) probe (2 mm; King et al. 1978). The WCM-2000 is calibrated according to the manufacturer instructions, which involve a dedicated test flight in cloud-free air. Each flight is also corrected for zero-offset bias using clear-air measurements},
doi = {10.5439/1465759},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Wed Jun 21 04:00:00 UTC 2017},
month = {Wed Jun 21 04:00:00 UTC 2017}
}
