skip to main content

Title: ARM: Sky radiation sensor: 1-min data with Dutton correction

Sky radiation sensor: 1-min data with Dutton correction
Authors:
Publication Date:
DOE Contract Number:
DE-AC05-00OR22725
Product Type:
Dataset
Research Org(s):
Atmospheric Radiation Measurement (ARM) Archive, Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (US)
Sponsoring Org:
USDOE Office of Science (SC), Biological and Environmental Research (BER)
Subject:
54 Environmental Sciences; Shortwave broadband diffuse downwelling irradiance; Shortwave broadband direct normal irradiance; Shortwave broadband total downwelling irradiance
OSTI Identifier:
1027760
  1. ARM focuses on obtaining continuous measurements—supplemented by field campaigns—and providing data products that promote the advancement of climate models. ARM data include routine data products, value-added products (VAPs), field campaign data, complementary external data products from collaborating programs, and data contributed by ARM principal investigators for use by the scientific community. Data quality reports, graphical displays of data availability/quality, and data plots are also available from the ARM Data Center. Serving users worldwide, the ARM Data Center collects and archives approximately 20 terabytes of data per month. Datastreams are generally available for download within 48 hours.
No associated Collections found.
  1. Broadband Radiometer Station (BRS) broadband shortwave and longwave 1-min radiation data with Dutton correction
  2. Solar and Infrared Radiation Observing Station (SIROS): 1-min data with Dutton correction
  3. Corrections for inaccuracy in Vaisala radiosonde RH measurements have been applied to ARM SGP radiosonde soundings. The magnitude of the corrections can vary considerably between soundings. The radiosonde measurement accuracy, and therefore the correction magnitude, is a function of atmospheric conditions, mainly T, RH, andmore » dRH/dt (humidity gradient). The corrections are also very sensitive to the RH sensor type, and there are 3 Vaisala sensor types represented in this dataset (RS80-H, RS90, and RS92). Depending on the sensor type and the radiosonde production date, one or more of the following three corrections were applied to the RH data: Temperature-Dependence correction (TD), Contamination-Dry Bias correction (C), Time Lag correction (TL). The estimated absolute accuracy of NIGHTTIME corrected and uncorrected Vaisala RH measurements, as determined by comparison to simultaneous reference-quality measurements from Holger Voemel's (CU/CIRES) cryogenic frostpoint hygrometer (CFH), is given by Miloshevich et al. (2006). « less
  4. SIRS: derived, correction of downwelling shortwave diffuse hemispheric measurements using Dutton and full algorithm
  5. The EC tower is operated as part of the Next Generation Ecosystem Experiment-Arctic (NGEE) at Barrow, Alaska. The tower is collecting flux data from the beginning of the thaw season, early June, and until conditions are completely frozen, early November. The tower is equipped withmore » a Gill R3-50 Sonic Anemometer, LI-7700 (CH4) sensor, a LI-7500A (CO2/H2O) sensor, and radiation sensors (Kipp and Zonen CNR-4 (four component radiometer), two LiCor LI-190 quantum sensors (PAR upwelling and downwelling), and a down-looking Apogee SI-111 infrared radiometer (surface temperature)). The sensors are remotely controlled, and communication with the tower allows us to retrieve information in real time. « less