Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

SPALLOOP

Software ·
DOI:https://doi.org/10.11578/dc.20230424.1· OSTI ID:code-105255 · Code ID:105255
 [1];  [1]
  1. Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

Boiler tubes in steam power plants experience tube blockages due to exfoliation of oxide grown on the inner side of the tubes. In extreme cases, significant tube blockages can lead to forced power plant outages. It is thus desired to predict through modeling the amount of tube blockage in order to inform power plant operators of possible forced outages. SpalLoop solves for the stress-strain equations in an axisymmetric geometry, tracking the stress/strain evolution during boiler operation including outages for the entire boiler tube length. At each operational outage, i.e., temperature excursions down to room temperature, the amount of exfoliated area for the entire tube loop is estimated the amount of tube blockage is predicted based assumed blockage geometry and site. The SpaLLoop code contains modules developed for oxide growth, stress analysis, tube loop geometry, blockage area by taking into account the following phenomena and features, (a) Plant operation schedule with periodic alternate full-load and partial-load regimes and shut-downs, i.e., temperature excursions from high-load to room temperature, (b) axisymmetric formulation for cylindrical tubes, (c) oxide growth in a temperature gradient with multiple oxide layers, (d) geometry of a boiler tube with a single tube loop or two tube loops, (e) temperature variation along the tube length based on hot gas temperature distribution outside the tube and inlet steam temperature, (f) non-uniform oxide growth along the tube length according to the local steam tube temperature, (g) exfoliated area module: at each operational outage considered, the amount of exfoliated area and exfoliated volume along the tube is estimated, (h) blockage module: at each operational outage considered, the exfoliated volume/mass for each tube loop is estimated from which the amount of tube blockage is predicted based on given blockage geometry (length, location, and geometry). The computer program is written in FORTRAN90. Its modular structure was sought for allowing the best flexibility in updating the program by implementing new constitutive equations due to availability of new material property data and/or new physical phenomena.

Site Accession Number:
7940
Software Type:
Scientific
License(s):
Other (Commercial or Open-Source)
Programming Language(s):
Fortran90
Research Organization:
Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
Sponsoring Organization:
USDOE

Primary Award/Contract Number:
AC05-00OR22725
DOE Contract Number:
AC05-00OR22725
Code ID:
105255
OSTI ID:
code-105255
Country of Origin:
United States

Similar Records

SPALLMAP
Software · Wed Mar 21 20:00:00 EDT 2018 · OSTI ID:code-45638

MANAGING OXIDE SCALE EXFOLIATION IN BOILERS WITH TP347H SUPERHEATER TUBES
Conference · Tue Dec 31 23:00:00 EST 2013 · OSTI ID:1126527

Oxide scale exfoliation and regrowth in TP347H superheater tubes: Oxide scale exfoliation and regrowth
Journal Article · Mon Jul 23 00:00:00 EDT 2012 · Materials and Corrosion · OSTI ID:1081910