Shipping package 9975-02130 was examined in K-Area following the identification of a nonconforming condition; the axial gap between the drum flange and upper fiberboard assembly exceeded the maximum allowed value of 1 inch. The average measured axial gap was 1.1 inches. The fiberboard assembly in this package contained moisture levels of {approx}14-24% wood moisture equivalent ({approx}12-19 wt%) This is moderately higher than typically seen in conforming packages, but not as high as seen on most packages which have exceeded the allowed axial gap. Small patches of mold were growing on portions of the lower fiber assembly, but the fiberboard appeared intact and with little apparent change in its integrity. The lead shield had a heavy layer of corrosion product, some of which flaked off easily. The thickness of several flakes was measured, and varied from 0.0016 to 0.0031 inch. However, additional corrosion product remained on the shield under the flaked regions, so the total thickness of corrosion product exceeds 0.0031 inch.

Research Organization:
Savannah River Site (SRS), Aiken, SC (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
DE-AC09-08SR22470
OSTI ID:
986755
Report Number(s):
SRNL-STI-2010-00402; TRN: US201018%%630
Country of Publication:
United States
Language:
English

Similar Records

EXAMINATION OF SHIPPING PACKAGES 9975-01818, 9975-01903 AND 9975-02287
Technical Report · Wed Nov 18 00:00:00 EST 2009 · OSTI ID:986755

Destructive Examination of Shipping Package 9975-02731
Technical Report · Wed Jun 01 00:00:00 EDT 2022 · OSTI ID:986755

MODEL 9975 LIFE EXTENSION PACKAGE 1 - FINAL REPORT
Technical Report · Fri Mar 04 00:00:00 EST 2011 · OSTI ID:986755