Passive Standoff Detection of RDX Residues on Metal Surfaces via Infrared Hyperspectral Imaging
Journal Article
·
· Analytical and Bioanalytical Chemistry, 395(2):337-348
Hyperspectral images of galvanized steel plates, each containing a stain of RDX, were recorded using a commercial longwave infrared imaging spectrometer. Demonstrations of passive RDX chemical detection at areal dosages between 16 and 90 µg / cm2 were carried out over practical stand-off ranges between 14 and 50 m. Efforts to develop better chemical anomaly and target detection through chemometric analyses are described.
- Research Organization:
- Pacific Northwest National Laboratory (PNNL), Richland, WA (US)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC05-76RL01830
- OSTI ID:
- 985009
- Report Number(s):
- PNNL-SA-64981
- Journal Information:
- Analytical and Bioanalytical Chemistry, 395(2):337-348, Journal Name: Analytical and Bioanalytical Chemistry, 395(2):337-348 Journal Issue: 2 Vol. 395; ISSN 1618-2642; ISSN 1618-2650
- Country of Publication:
- United States
- Language:
- English
Similar Records
Passive Infrared Hyperspectral Imaging for Standoff Detection of Tetryl Explosive Residue on a Steel Surface
Simultaneous standoff plume detection using a swept-ECQCL and passive hyperspectral imaging
Standoff imaging of chemicals using IR spectroscopy
Conference
·
Tue Jun 15 00:00:00 EDT 2010
·
OSTI ID:1038657
Simultaneous standoff plume detection using a swept-ECQCL and passive hyperspectral imaging
Conference
·
Mon Sep 12 00:00:00 EDT 2022
·
OSTI ID:1887867
Standoff imaging of chemicals using IR spectroscopy
Conference
·
Fri Dec 31 23:00:00 EST 2010
·
OSTI ID:1015709