Debuncher Energy Mismatch

Technical Report ·
DOI:https://doi.org/10.2172/984606· OSTI ID:984606
During the December 1999 startup of antiproton stacking, a quick measurement of the Debuncher momentum aperture was made. The measurement was done by turning off and de-tuning the Debuncher bunch rotation cavities and observing the Debuncher 75 MHz longitudinal schottky signal of the circulating antiprotons as shown in Figure 1. The frequency at the center of the plot corresponds to the rotation frequency of the Debuncher RF cavities. (The schottky signal and the bunch rotation frequency occur at the 127th and 90th harmonics of the revolution frequency, respectively.) Figure 1 shows that the Debuncher bunch rotation energy is offset from the middle of the Debuncher momentum aperture by about 0.7% (57 MeV). The measured value of momentum aperture using the width of the base of the signal shown in Figure 1 ({eta} = 0.006 ) is 3.9% (346 MeV). This is close to the design value of 4%, so the offset is probably not due to any asymmetric momentum aperture restrictions.
Research Organization:
Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States)
Sponsoring Organization:
USDOE Office of Science (SC), High Energy Physics (HEP) (SC-25)
DOE Contract Number:
AC02-07CH11359
OSTI ID:
984606
Report Number(s):
FERMILAB-PBAR-NOTE-629; oai:inspirehep.net:863495
Country of Publication:
United States
Language:
English

Similar Records

Momentum precooling in the debuncher ring for the Fermilab Tevatron I project
Conference · Mon Aug 01 00:00:00 EDT 1983 · IEEE Trans. Nucl. Sci.; (United States) · OSTI ID:5436251

Momentum precooling in the Debuncher ring for the Fermilab Tevatron-I project
Conference · Mon Feb 28 23:00:00 EST 1983 · OSTI ID:6053311

Phasing of Debuncher Stochastic Cooling Transverse Systems
Technical Report · Wed Mar 08 23:00:00 EST 2000 · OSTI ID:984628