This note will outline the sensitivity to emittance blowup of antiproton transfers due to quadrupole focussing and quadrupole steering errors in the 8 GeV AP3-P1 transfer line. It will be shown that these tolerances are much larger than the dipole steering tolerances discussed in PBAR Note 649. This note will use the lattice discussed in PBAR Note 648.
Research Organization:
Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States)
Sponsoring Organization:
USDOE Office of Science (SC), High Energy Physics (HEP) (SC-25)
DOE Contract Number:
AC02-07CH11359
OSTI ID:
984581
Report Number(s):
FERMILAB-PBAR-NOTE-653; oai:inspirehep.net:863818