For improved reproducibility of good operating conditions and ramp commissioning efficiency, new dual-plane slow orbit feedback during the energy ramp was implemented during run-10 in the Relativistic Heavy Ion Collider (RHIC). The orbit feedback is based on steering the measured orbit, after subtraction of the dispersive component, to either a design orbit or to a previously saved reference orbit. Using multiple correctors and beam position monitors, an SVD-based algorithm is used for determination of the applied corrections. The online model is used as a basis for matrix computations. In this report we describe the feedback design, review the changes made to realize its implementation, and assess system performance.
- Research Organization:
- Brookhaven National Laboratory (BNL) Relativistic Heavy Ion Collider
- Sponsoring Organization:
- Doe - Office Of Science
- DOE Contract Number:
- AC02-98CH10886
- OSTI ID:
- 984409
- Report Number(s):
- BNL--90818-2010-CP; KB0202011
- Country of Publication:
- United States
- Language:
- English
Similar Records
Near real-time ORM measurements and SVD matrix generation for 10 Hz global orbit feedback in RHIC
Optimization methodology for the global 10 Hz orbit feedback in RHIC
Orbit response matrix measurements for 10Hz global orbit feedback in RHIC
Conference
·
Mon Mar 28 00:00:00 EDT 2011
·
OSTI ID:1012261
Optimization methodology for the global 10 Hz orbit feedback in RHIC
Journal Article
·
Mon May 07 20:00:00 EDT 2018
· Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
·
OSTI ID:1438429
Orbit response matrix measurements for 10Hz global orbit feedback in RHIC
Technical Report
·
Fri Oct 01 00:00:00 EDT 2010
·
OSTI ID:993469