Wedge Absorber Design for the Muon Ionisation Cooling Experiment
In the Muon Ionisation Cooling Experiment (MICE), muons are cooled by ionisation cooling. Muons are passed through material, reducing the total momentum of the beam. This results in a decrease in transverse emittance and a slight increase in longitudinal emittance, but overall reduction of 6d beam emittance. In emittance exchange, a dispersive beam is passed through wedge-shaped absorbers. Muons with higher energy pass through more material, resulting in a reduction in longitudinal emittance as well as transverse emittance. We consider the cooling performance of different wedge materials and geometries and propose a set of measurements that would be made in MICE.We outline the resources these measurements would require and detail some constraints that guide the choice of wedge parameters.