Large eddy simulation of wire-wrapped fuel pins I: Hydrodynamics in a periodic array.

Conference ·
OSTI ID:977353
We present large-eddy simulations of flow in a wire-wrapped fuel assembly at subchannel Reynolds numbers of Re{sub h} = 4684-29184. The domain consists of a single pin in a hexagonally periodic array, corresponding to two interior subchannels. Periodic boundary conditions are also used in the axial direction over a single wire-wrap period.