Measuring current emission and work functions of large thermionic cathodes.
- Clifford M.
As one component of the nations Stockpile Stewardship program, Los Alamos National Laboratory is constructing a 20 MeV, 2 kA (with a 4 kA upgrade capability), 3ps induction linac for doing x-ray radiography of explosive devices. The linac is one leg of a facility called the Dual-Axis Radiography Hydrodynamic Test Facility (DARHT). The electron gun is designed to operate at 3.2 MV. The gun is a Pierce type design and uses a 6.5' cathode for 2 kA operation and an 8' cathode for 4 kA operation. We have constructed a small facility called the Cathode Test Stand (CTS) to investigate engineering and physics issues regarding large thermionic dispenser-cathodes. In particular, we have looked at the issues of temperature uniformity on the cathode surface and cathode quality as measured by its work function. We have done thermal imaging of both 8' and 6.5' cathodes. Here we report on measurements of the cathode work function, both the average value and how it vanes across the face of the cathode.
- Research Organization:
- Los Alamos National Laboratory
- Sponsoring Organization:
- DOE
- OSTI ID:
- 975915
- Report Number(s):
- LA-UR-01-6870
- Country of Publication:
- United States
- Language:
- English
Similar Records
A flat-cathode thermionic injector for the PHERMEX Radiographic Facility
A flat-cathode thermionic injector for the PHERMEX Radiographic Facility