A 75-keV, 145-mA proton injector
Conference
·
OSTI ID:975683
- Terry L.
- Lash D.
- Debora M.
- J. David
- Horace V.
- Matthew W.
- Michael E.
- David S.
- Thomas J.
- Adrian A.
A dc and pulsed-mode 75-keV proton injector has been developed and is used in characterization of a continuous-wave (cw) 6.7-MeV, 100-mA radio-frequency quadrupole (RFQ). The injector is used frequently at the full RFQ design power (100-mA, 6.7-MeV) where the RFQ admittance (1rms, normalized) is 0.23 ({pi}mm-mrad). The injector includes a 2.45-GHz microwave proton source and a beam space-charge-neutralized, two magnetic-solenoid, low-energy beam-transport system (LEBT). The design RFQ beam transmission of 95% has been demonstrated at 100-mA RFQ output current.