Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

ANFO cylinder tests

Conference ·
DOI:https://doi.org/10.1063/1.1483507· OSTI ID:975570
Cylinder test data is reported for commercially available prilled ANFO (ammonium-nitrate/fuel-oil) at 0.93 ,g/cc density and ambient temperature. The tests were four-inch inner diameter, with wall-thickness and length scaled from the standard one-inch test (0.4 inch and 48 inch, respectively). The wall expansion was measured with a rotating mirror streak camera and the velocity was measured by fine-wire pin switches, in the standard manner. The wall expansion trajectory is much smoother than for conventional explosives, which show a pronounced jump-off with subs uent ring-up. This observation is consistent with a broadened detohation shock in the granular bed. ?he data is analyzed for equation-of-state information and JWL parameters are given.
Research Organization:
Los Alamos National Laboratory
Sponsoring Organization:
DOE
OSTI ID:
975570
Report Number(s):
LA-UR-01-3340
Country of Publication:
United States
Language:
English

Similar Records

Detonation shock dynamics calibration for non-ideal HE: ANFO
Journal Article · Wed Dec 31 23:00:00 EST 2008 · OSTI ID:992199

Cylinder Test Specification
Technical Report · Fri Oct 01 00:00:00 EDT 1999 · OSTI ID:15135

W-76 PBX 9501 cylinder tests
Technical Report · Wed Jul 01 00:00:00 EDT 1998 · OSTI ID:639796