The Advanced Photon Source (APS) particle accumulator ring (PAR) has dual rf systems: a CW-mode fundamental rf system (RF1) operating at 9.77 MHz that accumulates multiple linac pulses into a 0.8-ns bunch, and a 12th harmonic rf (RF12) that compresses the bunch length further to 0.34 ns for injection into the booster. The RF12 capture process is critical for optimal performance of the PAR. We investigated the effects of beam loading during the RF12 capture and bunch length compression processes with both spectrum analysis and streak camera imaging. Based on these observations, a new timing scheme for the RF12 tuner and power control was implemented, which has substantially improved the performance of the PAR. We report our observation, the new timing scheme, and beam parameters after optimization.