Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

RADIOXENON MEASUREMENTS WITH THE PHOSWATCH DETECTOR SYSTEM

Conference ·
OSTI ID:973439
Many of the radioxenon detector systems used in the International Monitoring System and in other applications employ beta/gamma coincidence detection to achieve high sensitivity. In these systems, the coincidence detection is implemented by requiring simultaneous signals from separate beta and gamma detectors. While very sensitive to small amounts of radioxenon, this approach requires careful calibration and gain matching of several detectors and photomultiplier tubes. An alternative approach is the use of a phoswich detector in which beta-gamma coincidences are detected by pulse shape analysis. The phoswich requires only a single photomultiplier tube and thus is easier to set up and calibrate, and can be assembled into a more compact and robust system. In the past, we have developed a COTS detector system, named PhosWatch, which consists of a CsI(Tl)/BC-404 phoswich detector, digital readout electronics, and on-board software to perform the pulse shape analysis. Several units of this system have been manufactured and are now evaluated at several radioxenon research laboratories. In this paper, we will report results from production tests and some of the evaluations, including a side-by-side comparison of a SAUNA detector and a PhosWatch system using atmospheric radioxenon samples. In addition, we will show initial results obtained with a higher speed version of the readout electronics, digitizing at 500 MHz and thus able to better resolve the fast pulses from the BC-404.
Research Organization:
Pacific Northwest National Laboratory (PNNL), Richland, WA (US)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC05-76RL01830
OSTI ID:
973439
Report Number(s):
PNNL-SA-65863; NN2003000
Country of Publication:
United States
Language:
English

Similar Records

A PHOSWICH WELL DETECTOR FOR RADIOXENON MONITORING
Journal Article · Tue Aug 21 00:00:00 EDT 2007 · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, 579(1):431-436 · OSTI ID:915300

Characterization of Phoswich Well Detectors for Radioxenon Monitoring
Conference · Sat Sep 01 00:00:00 EDT 2007 · OSTI ID:919308

Development of a phoswich detector system for radioxenon monitoring
Journal Article · Wed Dec 02 23:00:00 EST 2009 · Journal of Radioanalytical and Nuclear Chemistry, 282(3):681-685 · OSTI ID:969167