Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

FEL GAIN LENGTH AND TAPER MEASUREMENTS AT LCLS

Conference ·
OSTI ID:973380
We present experimental studies of the gain length and saturation power level from 1.5 nm to 1.5 Angstroms at the Linac Coherent Light Source (LCLS). By disrupting theFEL process with an orbit kick, we are able to measure the X-ray intensity as a function of undulator length. This kick method is cross-checked with the method of removing undulator sections. We also study the FEL-induced electron energy loss after saturation to determine the optimal taper of the undulator K values. The experimental results are compared to theory and simulations.
Research Organization:
Ernest Orlando Lawrence Berkeley National Laboratory, Berkeley, CA (US)
Sponsoring Organization:
Accelerator& Fusion Research Division
DOE Contract Number:
AC02-05CH11231
OSTI ID:
973380
Report Number(s):
LBNL-2537E
Country of Publication:
United States
Language:
English

Similar Records

FEL Gain Length and Taper Measurements at LCLS
Conference · Fri Jul 30 00:00:00 EDT 2010 · OSTI ID:984330

Effects of Tapered Betafunction in the LCLS Undulators
Conference · Fri Sep 30 00:00:00 EDT 2005 · OSTI ID:878374

Tapered undulator for SASE FELs
Conference · Fri Sep 14 00:00:00 EDT 2001 · OSTI ID:788084