FEL GAIN LENGTH AND TAPER MEASUREMENTS AT LCLS
Conference
·
OSTI ID:973380
We present experimental studies of the gain length and saturation power level from 1.5 nm to 1.5 Angstroms at the Linac Coherent Light Source (LCLS). By disrupting theFEL process with an orbit kick, we are able to measure the X-ray intensity as a function of undulator length. This kick method is cross-checked with the method of removing undulator sections. We also study the FEL-induced electron energy loss after saturation to determine the optimal taper of the undulator K values. The experimental results are compared to theory and simulations.