skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Sensivitity improvement in low-profile distributed detector systems for tracking sources in transit.

Conference ·

The RadTrac real-time detection and tracking software runs on a laptop computer networked to gamma-radiation detectors. A probabilistic estimate for source position is generated by combining measured count rate data with a first-principles stochastic model for the space and time dependence of count rates and knowledge of detector intrinsic efficiency. Recent development work has focused on improving RadTrac sensitivity in low-count rate situations. A method has been developed for processing count rates by energy according to that part of the energy spectrum with the greatest signal-to-noise ratio. In addition a method has been developed that places constraints on the solution that are physically appropriate when count rates approach background. In both instances experiments with a weak source confirmed the uncertainty in estimated position is reduced.

Research Organization:
Argonne National Lab. (ANL), Argonne, IL (United States)
Sponsoring Organization:
USDOE Office of Science (SC)
DOE Contract Number:
DE-AC02-06CH11357
OSTI ID:
971142
Report Number(s):
ANL/NE/CP-59033; TRN: US201003%%592
Resource Relation:
Conference: 2007 IEEE Conference on Technologies for Homeland Security Enhancing Critical Infrastructure Dependability; May 16, 2007 - May 17, 2007; Woburn, MA
Country of Publication:
United States
Language: