Design and characterization of an UHV compatible artificial channel cut monochromator.
We present design and characterization results of a novel ultra-high-vacuum-compatible artificial channel-cut monochromator that has been installed at the undulator beamline 8-ID-I at the Advanced Photon Source. The monochromator has been designed to meet the challenging stability and optical requirements of the x-ray photon correlation spectroscopy program hosted at this beamline. In particular, the device incorporates a novel in-vacuum sine-bar drive mechanism for the combined pitch motion of the two crystals and a flexure-based high-stiffness weak-link mechanism for fine tuning the pitch and roll of the second crystal relative to the first crystal.
- Research Organization:
- Argonne National Laboratory (ANL)
- Sponsoring Organization:
- SC
- DOE Contract Number:
- AC02-06CH11357
- OSTI ID:
- 971125
- Report Number(s):
- ANL/XSD/CP-119234
- Country of Publication:
- United States
- Language:
- ENGLISH
Similar Records
Initial Characterization and Design of an UHV-Compatible Artificial Channel-Cut Monochromator
Initial characterization and design of an ultra-high-vacuum-compatible artificail channel-cut monochromator.
Precision mechanical design of an UHV-compatible artificial channel-cut x-ray monochromator.
Journal Article
·
Thu Jan 18 23:00:00 EST 2007
· AIP Conference Proceedings
·
OSTI ID:21052668
Initial characterization and design of an ultra-high-vacuum-compatible artificail channel-cut monochromator.
Conference
·
Sun Dec 31 23:00:00 EST 2006
·
OSTI ID:970765
Precision mechanical design of an UHV-compatible artificial channel-cut x-ray monochromator.
Conference
·
Sun Dec 31 23:00:00 EST 2006
·
OSTI ID:981638