Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

A multi-threshold sampling method for TOF PET signal processing

Journal Article · · Nuclear Instruments and Methods

As an approach to realizing all-digital data acquisition for positron emission tomography (PET), we have previously proposed and studied a multithreshold sampling method to generate samples of a PET event waveform with respect to a few user-defined amplitudes. In this sampling scheme, one can extract both the energy and timing information for an event. In this paper, we report our prototype implementation of this sampling method and the performance results obtained with this prototype. The prototype consists of two multi-threshold discriminator boards and a time-to-digital converter (TDC) board. Each of the multi-threshold discriminator boards takes one input and provides up to 8 threshold levels, which can be defined by users, for sampling the input signal. The TDC board employs the CERN HPTDC chip that determines the digitized times of the leading and falling edges of the discriminator output pulses. We connect our prototype electronics to the outputs of two Hamamatsu R9800 photomultiplier tubes (PMTs) that are individually coupled to a 6.25 x 6.25 x 25mm{sup 3} LSO crystal. By analyzing waveform samples generated by using four thresholds, we obtain a coincidence timing resolution of about 340 ps and an {approx}18% energy resolution at 511 keV. We are also able to estimate the decay-time constant from the resulting samples and obtain a mean value of 44 ns with an {approx}9 ns FWHM. In comparison, using digitized waveforms obtained at a 20 GSps sampling rate for the same LSO/PMT modules we obtain {approx}300 ps coincidence timing resolution, {approx}14% energy resolution at 511 keV, and {approx}5 ns FWHM for the estimated decay-time constant. Details of the results on the timing and energy resolutions by using the multi-threshold method indicate that it is a promising approach for implementing digital PET data acquisition.

Research Organization:
Ernest Orlando Lawrence Berkeley National Laboratory, Berkeley, CA (US)
Sponsoring Organization:
Life Sciences Division
DOE Contract Number:
AC02-05CH11231
OSTI ID:
970812
Report Number(s):
LBNL-2262E
Journal Information:
Nuclear Instruments and Methods, Journal Name: Nuclear Instruments and Methods Vol. A-602; ISSN 0029-554X; ISSN NUIMAL
Country of Publication:
United States
Language:
English

Similar Records

Factors influencing timing resolution in a commercial LSO PETcamera
Journal Article · Sat Oct 23 00:00:00 EDT 2004 · IEEE Transactions on Nuclear Science · OSTI ID:881727

Evaluation of cerium doped lutetium oxyorthosilicate (LSO) scintillation crystal for PET
Journal Article · Sun Aug 01 00:00:00 EDT 1993 · IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States) · OSTI ID:6011870

X-ray and gamma ray detector readout system
Patent · Tue Oct 19 00:00:00 EDT 2010 · OSTI ID:1016123