Impact of High-Order Multipole Errors in the NSLS-II Quadrupoles and Sectupoles on Dynamic and Momentum Aperture
Conference
·
OSTI ID:970509
Successful operation of NSLS-II requires sufficient dynamic aperture for injection, as well as momentum aperture for Touschek lifetime. We explore the dependence of momentum and dynamic aperture on higher-order multipole field errors in the quadrupoles and sextupoles. We add random and systematic multipole errors to the quadrupoles and sextupoles and compute the effect on dynamic aperture. We find that the strongest effect is at negative momentum, due to larger closed orbit excursions. Adding all the errors based on the NSLS-II specifications, we find adequate dynamic and momentum aperture.