Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Comparison of slope and height profiles for flat synchrotron x-ray mirrors measured with a long trace profiler and a Fizeau interferometer.

Conference ·
OSTI ID:970373
Long trace profilers (LTPS) have been used at many synchrotron radiation laboratories worldwide for over a decade to measure surface slope profiles of long grazing incidence x-ray mirrors. Phase measuring interferometers (PMIs) of the Fizeau type, on the other hand, are being used by most mirror manufacturers to accomplish the same task. However, large mirrors whose dimensions exceed the aperture of the Fizeau interferometer require measurements to be carried out at grazing incidence, and aspheric optics require the use of a null lens. While an LTP provides a direct measurement of ID slope profiles, PMIs measure area height profiles from which the slope can be obtained by a differentiation algorithm. Measurements of the two types of instruments have been found by us to be in good agreement, but to our knowledge there is no published work directly comparing the two instruments. This paper documents that comparison. We measured two different nominally flat mirrors with both the LTP in operation at the Advanced Photon Source (a type-II LTP) and a Fizeau-type PMI interferometer (Wyko model 6000). One mirror was 500 mm long and made of Zerodur, and the other mirror was 350 mm long and made of silicon. Slope error results with these instruments agree within nearly 100% (3.11 {+-} 0.15 {micro}rad for the LTP, and 3.11 {+-} 0.02 {micro}rad for the Fizeau PMI interferometer) for the medium quality Zerodur mirror with 3 {micro}rad rms nominal slope error. A significant difference was observed with the much higher quality silicon mirror. For the Si mirror, slope error data is 0.39 {+-} 0.08 {micro}rad from LTP measurements but it is 0.35 {+-} 0.01 {micro}rad from PMI interferometer measurements. The standard deviations show that the Fizeau PMI interferometer has much better measurement repeatability.
Research Organization:
Argonne National Laboratory (ANL)
Sponsoring Organization:
SC
DOE Contract Number:
AC02-06CH11357
OSTI ID:
970373
Report Number(s):
ANL/XSD/CP-60020
Country of Publication:
United States
Language:
ENGLISH

Similar Records

Error reduction techniques for measuring long synchrotron mirrors
Conference · Wed Jul 01 00:00:00 EDT 1998 · OSTI ID:666054

METROLOGICAL CHALLENGES OF SYNCHROTRON RADIATION OPTICS.
Conference · Tue May 25 00:00:00 EDT 1999 · OSTI ID:11474

Advances in precision mirror figure metrology (abstract)
Journal Article · Tue Dec 31 23:00:00 EST 1991 · Review of Scientific Instruments; (United States) · OSTI ID:5519001