Addendum 6 to CSAR 79-038 out-of-hood plutonium storage (burial box)
The Addendum considered an increase in the limit of fissile material in a stacked container array to 500 grams. In other words, the sum of fissile material in an array of containers is limited to 500 grams, regardless of whether the containers are stacked or not. The results of this evaluation indicates that with the modification of the fissile limits described, the system of a container array will stay sub-critical.
- Research Organization:
- Westinghouse Hanford Co., Richland, WA (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC06-87RL10930
- OSTI ID:
- 97037
- Report Number(s):
- WHC-SD-SQA-CSA-20397; ON: DE95015550; TRN: 95:019302
- Resource Relation:
- Other Information: PBD: 14 Jun 1995
- Country of Publication:
- United States
- Language:
- English
Similar Records
CSAR 79-034 ADDENDUM 2, storing the man-basket in the process cell in 236-Z Building, Plutonium Finishing Plant/Plutonium Reclamation Facility
Addendum 1 to CSER 79-002, use of the 150 gram fissile limit in Room 187 of PFP
Addendum 2 to CSER 79-002: Extension of the 150 gram fissile limit used in room 187 of PFP
Technical Report
·
Tue Oct 25 00:00:00 EDT 1994
·
OSTI ID:97037
Addendum 1 to CSER 79-002, use of the 150 gram fissile limit in Room 187 of PFP
Technical Report
·
Tue Oct 18 00:00:00 EDT 1994
·
OSTI ID:97037
Addendum 2 to CSER 79-002: Extension of the 150 gram fissile limit used in room 187 of PFP
Technical Report
·
Tue Dec 13 00:00:00 EST 1994
·
OSTI ID:97037