The Effects of Pressure on the Laser Initiation of TiHx/KClO4 and Other Pyrotechnics
- Mound Plant (MOUND), Miamisburg, OH (United States)
The ignition thresholds of TiHx/KCLO4, Mg/Teflon, and an A1-torch mix are measured as a function of gas pressure for ignition by 514.5 nm pulses from an argon ion laser. The TiHx/KCLO4 system in argon gas has three distinct pressure regimes. The thresholds are very high below about 0.3 MPa, decrease rapidly between 0.3 and 1.5 MPa, and decrease gradually and become constant between 1.5 and 7 MPa. Mg/Teflon and the A1-torch mix also have decreasing thresholds with increasing gas pressures and decreasing pellet densities. Ignition pulse lengths between 0.25 and 20 milliseconds at a spot diameter of 65 microns in the TiHx/KCLO4 system indicate that the thresholds are predominantly power, not energy, thresholds for pulses longer than one millisecond. The increase in threshold power below one millisecond is consistent with a calculated time to reach thermal equilibrium of 0.96 milliseconds. The effect of beam diameters between 40 and 175 microns on the TiHx/KCLO4 thresholds is consistent with ignitions occurring at approximately the same temperature at the center of the beam. TiHx/KCLO4 and Zr/KCLO4/Viton/Graphite pyrotechnics are also ignited in sealed devices through sapphire windows. Ignition thresholds are comparable to those on open surfaces in pressures of 0.1 to 0.5 MPa which suggests that samples first decompose and ignite under a pocket of pressure. Ignition failures in TiHx/KCLO4 and in low density Zr/KCLO4/Viton/Graphite samples are attributed to increased porosity and/or gaps near the windows which allow reaction products to escape from the ignition zone.
- Research Organization:
- Mound Plant (MOUND), Miamisburg, OH (United States)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC04-76DP00053
- OSTI ID:
- 968982
- Report Number(s):
- MLM--3533(OP)
- Country of Publication:
- United States
- Language:
- English
Similar Records
Laser initiation of TiH/sub x//KClO/sub 4/ (x = 0. 2, 0. 65, 1. 65). [Argon laser]
Electrical resistivity of TiH/sub x/KClO/sub 4/
Load cell testing of TiH/sub x//KClO/sub 4/ pyrotechnic actuators
Technical Report
·
Tue Jul 01 00:00:00 EDT 1986
·
OSTI ID:5452931
Electrical resistivity of TiH/sub x/KClO/sub 4/
Conference
·
Sat Dec 31 23:00:00 EST 1977
·
OSTI ID:6699900
Load cell testing of TiH/sub x//KClO/sub 4/ pyrotechnic actuators
Conference
·
Sat Dec 31 23:00:00 EST 1977
·
OSTI ID:7090509