AISI Type 304L (304L) stainless steel was recommended as a suitable material of construction for the new Hazardous Low Level Waste Processing Tanks (HLLWPT). This report documents the second phase of a coupon immersion test program to determine the susceptibility of 304L to localized attack in a variety of simulated wastes. The coupon test results confirmed the conclusions that were made from the first phase of the test program. First, 304L is a suitable material of construction for the new waste tanks. Second, the agreement between the cyclic polarization tests and the coupon immersion tests demonstrates that cyclic polarization can be used to predict the susceptibility of a material to localized corrosion in these wastes. In addition to the tests performed on 304L, tests were performed on ASTM A537 carbon steel (A537) and Incoloy 825 (I825). Neither 304L nor I825 was susceptible to attack, while A537 experienced varying degrees of attack in the different wastes. Observations on the surface attack and corrosion products on A537 were used to elucidate the mechanism by which A537 corrodes in these wastes.