Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Predicting the lifetime of fluorosilicone O-rings.

Journal Article · · Proposed for publication in Polymer Degradation and Stability.
OSTI ID:966255

Long-term (up to 1000 days) accelerated oven-aging studies on a commercial fluorosilicone o-ring seal are used to predict the sealing lifetime at room temperature (23 C). The study follows force decay (relaxation) on squeezed o-ring material using isothermal compression stress relaxation (CSR) techniques. The relaxation is normally a complex mix of reversible physical effects and non-reversible chemical effects but we utilize an over-strain approach to quickly achieve physical equilibrium. This allows us to concentrate the measurements on the chemical relaxation effects of primary interest to lifetime assessment. The long-term studies allow us to access a fairly broad temperature range (80-138 C) which results in improved modeling of the temperature dependence of the accelerated data. Non-Arrhenius behavior is observed with evidence of a significant lowering of the activation energy at the lowest accelerated aging temperature (80 C). This observation is consistent with numerous recent accelerated aging studies that probed temperature ranges large enough to observe similar non-Arrhenius behavior. The extrapolated predictions imply that significant loss of sealing force requires on the order of 50-100 years at 23 C. Field aging results out to 25 years at 23 C are shown to be in reasonable accord with the significant change in Arrhenius slope observed from the accelerated aging study.

Research Organization:
Sandia National Laboratories
Sponsoring Organization:
USDOE
DOE Contract Number:
AC04-94AL85000
OSTI ID:
966255
Report Number(s):
SAND2008-7481J
Journal Information:
Proposed for publication in Polymer Degradation and Stability., Journal Name: Proposed for publication in Polymer Degradation and Stability.
Country of Publication:
United States
Language:
English

Similar Records

Fluorosilicone and silicone o-ring aging study.
Technical Report · Mon Oct 01 00:00:00 EDT 2007 · OSTI ID:922071

Validation of improved methods for predicting long-term elastomeric seal lifetimes from compression stress-relaxation and oxygen consumption techniques.
Journal Article · Fri Feb 28 23:00:00 EST 2003 · Proposed for publication in Polymer Degradation and Stability. · OSTI ID:917488

Methods for Predicting More Confident Lifetimes of Seals in Air Environments
Journal Article · Thu Mar 04 23:00:00 EST 1999 · Rubber Chemistry and Technology · OSTI ID:4252