Analysis of Enriched Uranyl Nitrate in Nested Annular Tank Array
Two series of experiments were performed at the Rocky Flats Critical Mass Laboratory during the 1980s using highly enriched (93%) uranyl nitrate solution in annular tanks. [1, 2] Tanks were of typical sizes found in nuclear production plants. Experiments looked at tanks of varying radii in a co-located set of nested tanks, a 1 by 2 array, and a 1 by 3 array. The co-located set of tanks had been analyzed previously [3] as a benchmark for inclusion within the International Handbook of Evaluated Criticality Safety Benchmark Experiments. [4] The current study represents the benchmark analysis of the 1 by 3 array of a series of nested annular tanks. Of the seventeen configurations performed in this set of experiments, twelve were evaluated and nine were judged as acceptable benchmarks.
- Research Organization:
- Idaho National Laboratory (INL)
- Sponsoring Organization:
- DOE - NE
- DOE Contract Number:
- AC07-99ID13727
- OSTI ID:
- 961916
- Report Number(s):
- INL/CON-09-15217
- Country of Publication:
- United States
- Language:
- English
Similar Records
Experimental critical parameters of enriched uranium solution in annular tank geometries
Analysis of High Enriched Uranyl Nitrate Solution Containing Cadmium