Small-Scale Safety and Thermal Characterization of 3,3'-diamino-4,4'-azoxyfurazan (DAAF)

Technical Report ·
DOI:https://doi.org/10.2172/957592· OSTI ID:957592

Small-scale safety testing has been completed on 3,3{prime}-diamino 4,4{prime}-azoxyfurazan (DAAF). The relative sensitivity of DAAF against various stimuli was evaluated. DAAF shows no observable sensitivity to friction or static spark. It has impact sensitivity approaching that of TATB. Using the One Dimensional Time to Explosion (ODTX) apparatus to measure thermal response, DAAF shows similar sensitivity to TNT and HMX. DSC and the CRT were also used to evaluate the thermal stability of DAAF under various conditions.

Research Organization:
Lawrence Livermore National Laboratory (LLNL), Livermore, CA
Sponsoring Organization:
USDOE
DOE Contract Number:
W-7405-ENG-48
OSTI ID:
957592
Report Number(s):
UCRL-TR-231649
Country of Publication:
United States
Language:
English

Similar Records

Intermolecular Stabilization of 3,3'-Diamino-4,4'-azoxyfurazan (DAAF) Compressed to 20 GPa
Journal Article · Thu Jul 10 00:00:00 EDT 2014 · Journal of Physical Chemistry. A, Molecules, Spectroscopy, Kinetics, Environment, and General Theory · OSTI ID:1354409

Use of 3,3'-diamino-4,4'-azoxyfurazan and 3,3'-diamino-4,4'-azofurazan as insensitive high explosive materials