High-Current Effects in The PEP-II Storage Rings

Conference · · Conf.Proc.C0806233:WEPP041,2008
OSTI ID:957417
High beam currents in PEP-II have been a challenge for vacuum system and ring components. For the {approx} 1 cm long bunches peak currents exceed 100 A and modest impedance can give rise to voltage spikes and discharges. During the last two runs, difficulties arose from rf seals at the 'flex flanges' in the HER. High temperatures were seen and the seals turned out to be severely damaged by discharges. In the LER, the horizontal stripline kickers of the bunch-by-bunch feedback system experiences breakdown at high bunch current-Macor pins installed for mechanical stability turned out to be a weak spot causing discharges. Finally, in the HER an experiment to shorten the ion-clearing gap in the beam revealed signs of ion-induced instability indicating that the HER has been operating quite close to the stability limit. The effects shown here are relevant to future high-intensity electron and positron rings like SuperB and PEP-X.
Research Organization:
Stanford Linear Accelerator Center (SLAC)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC02-76SF00515
OSTI ID:
957417
Report Number(s):
SLAC-PUB-13677
Conference Information:
Journal Name: Conf.Proc.C0806233:WEPP041,2008
Country of Publication:
United States
Language:
English

Similar Records

The PEP-II abort kicker system
Conference · Tue Jul 01 00:00:00 EDT 1997 · OSTI ID:513519

The Abort Kicker System for the PEP-II Storage Rings at SLAC.
Technical Report · Fri Jun 20 00:00:00 EDT 2003 · OSTI ID:813175

A zero-length bellows for the PEP-II High-Energy Ring
Conference · Tue Aug 01 00:00:00 EDT 1995 · OSTI ID:238586