Development of a model for predicting transient hydrogen venting in 55-gallon drums
Conference
·
OSTI ID:956600
- Los Alamos National Laboratory
Remote drum venting was performed on a population of unvented high activity drums (HAD) in the range of 63 to 435 plutonium equivalent Curies (PEC). These 55-gallon Transuranic (TRU) drums will eventually be shipped to the Waste Isolation Pilot Plant (WIPP). As a part of this process, the development of a calculational model was required to predict the transient hydrogen concentration response of the head space and polyethylene liner (if present) within the 55-gallon drum. The drum and liner were vented using a Remote Drum Venting System (RDVS) that provided a vent sampling path for measuring flammable hydrogen vapor concentrations and allow hydrogen to diffuse below lower flammability limit (LFL) concentrations. One key application of the model was to determine the transient behavior of hydrogen in the head space, within the liner, and the sensitivity to the number of holes made in the liner or number of filters. First-order differential mass transport equations were solved using Laplace transformations and numerically to verify the results. the Mathematica 6.0 computing tool was also used as a validation tool and for examining larger than two chamber systems. Results will be shown for a variety of configurations, including 85-gallon and 110-gallon overpack drums. The model was also validated against hydrogen vapor concentration assay measurements.
- Research Organization:
- Los Alamos National Laboratory (LANL)
- Sponsoring Organization:
- DOE
- DOE Contract Number:
- AC52-06NA25396
- OSTI ID:
- 956600
- Report Number(s):
- LA-UR-08-07516; LA-UR-08-7516
- Country of Publication:
- United States
- Language:
- English
Similar Records
Drum venting system design and fabrication
Fire testing of 55 gallon metal waste drums for dry waste storage
JUSTIFICATION FOR A LIMIT OF 15 PERCENT HYDROGEN IN A 55 GALLON DRUM
Journal Article
·
Sat Dec 30 23:00:00 EST 1995
· Transactions of the American Nuclear Society
·
OSTI ID:186500
Fire testing of 55 gallon metal waste drums for dry waste storage
Technical Report
·
Thu Jul 01 00:00:00 EDT 1993
·
OSTI ID:10108540
JUSTIFICATION FOR A LIMIT OF 15 PERCENT HYDROGEN IN A 55 GALLON DRUM
Technical Report
·
Wed Jan 03 23:00:00 EST 2007
·
OSTI ID:901429
Related Subjects
12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES
97 MATHEMATICS AND COMPUTING
CONTAINERS
FILTERS
FLAMMABILITY
HOLES
HYDROGEN
LAPLACE TRANSFORMATION
LINERS
MASS TRANSFER
MEETINGS
PLUTONIUM
POLYETHYLENES
RANGE
SAMPLING
SENSITIVITY
TRANSIENTS
VALIDATION
VAPORS
VENTS
WASTE MANAGEMENT
WIPP
97 MATHEMATICS AND COMPUTING
CONTAINERS
FILTERS
FLAMMABILITY
HOLES
HYDROGEN
LAPLACE TRANSFORMATION
LINERS
MASS TRANSFER
MEETINGS
PLUTONIUM
POLYETHYLENES
RANGE
SAMPLING
SENSITIVITY
TRANSIENTS
VALIDATION
VAPORS
VENTS
WASTE MANAGEMENT
WIPP