Effect of humidity on the filter pressure drop
- Institut de Protection et de Surete Nucleaire, Gif-sur-Yvette (France)
The effects of humidity on the filter pressure drop have been reported in some previous studies in which it is difficult to draw definite conclusions. These studies show contradictory effects of humidity on the pressure drop probably due to differences in the hygroscopicity of the test aerosols. The objective of this paper is to present experimental results on the evolution of the filter pressure drop versus mass loading, for different test aerosols and relative humidities. Present results are compared to those found in various publication. An experimental device has been designed to measure filter pressure drop as the function of the areal density for relative humidity varying in the range of 9 % to 85 %. Experiments have been conducted with hygroscopic: (CsOH) and nonhygroscopic aerosols (TiO{sub 2}). Cesium hydroxyde (CsOH) of size of 2 {mu} M AMMD has been generated by an ultrasonic generator and the 0.7 {mu}m AMMD titanium oxyde has been dispersed by a {open_quotes}turn-table{close_quotes} generator. As it is noted in the BISWAS`publication [3], present results show, in the case of nonhygroscopic aerosols, a linear relationship of pressure drop to mass loading. For hygroscopic aerosols two cases must be considered: for relative humidity below the deliquescent point of the aerosol, the relationship of pressure drop to mass loading remains linear; above the deliquescent point, the results show a sudden increase in the pressure drop and the mass capacity of the filter is drastically reduced.
- Research Organization:
- USDOE Assistant Secretary for Environment, Safety, and Health, Washington, DC (United States). Office of Environmental Guidance; Nuclear Regulatory Commission, Washington, DC (United States). Office of Nuclear Regulatory Research; International Society of Nuclear Air Treatment Technologies, Inc., Batavia, OH (United States); Harvard Univ., Boston, MA (United States). Harvard Air Cleaning Lab.
- OSTI ID:
- 95649
- Report Number(s):
- NUREG/CP--0141; CONF-940738--; ON: TI95007828
- Country of Publication:
- United States
- Language:
- English
Similar Records
Effect of humidity and particle hygroscopicity on the mass loading capacity of high efficiency particulate air (HEPA) filters
Study of the effect of humidity, particle hygroscopicity and size on the mass loading capacity of HEPA filters
Study of the effect of humidity, particle hygroscopicity and size on the mass loading capacity of HEPA filters
Journal Article
·
Thu Jul 01 00:00:00 EDT 1993
· Aerosol Science and Technology; (United States)
·
OSTI ID:5685673
Study of the effect of humidity, particle hygroscopicity and size on the mass loading capacity of HEPA filters
Thesis/Dissertation
·
Tue Dec 31 23:00:00 EST 1991
·
OSTI ID:10172571
Study of the effect of humidity, particle hygroscopicity and size on the mass loading capacity of HEPA filters
Conference
·
Tue Dec 31 23:00:00 EST 1991
·
OSTI ID:7270999