High-gradient SRF R&D for ILC at Jefferson Lab
Jefferson Lab plays an active role in high-gradient SRF R&D in the frame work of the internationally coordinated ILC S0 program. The S0 aim is to push the yield at 35 MV/m in 9-cell cavities. So far, twelve cavities have been electropolishing (EP) processed and RF tested by using the state-of-the-art recipes at JLab, in close collaboration with FNAL and KEK. Seven of them reached a best gradient of over 31.5 MV/m. Understanding gradient limiting mechanisms in real 9-cell cavities is an important component of our studies. Thermometry and high-resolution optical inspection are used to locate and understand the source of gradient limits. Experimenting with selective cavities is still a necessary method for process optimization. One example is the first demonstration of 35 MV/m without detectable Bremsstrahlung X-ray after a light EP is applied to a previously heavy BCP etched 7-cell cavity. Some new understanding has been gained with regard to quench behaviors, field emission behaviors as
- Research Organization:
- Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC05-060R23177
- OSTI ID:
- 956065
- Report Number(s):
- JLAB-ACC-08-893; DOE/OR/23177-0511; TRN: US1004862
- Resource Relation:
- Conference: Poster compiled for LINAC2008
- Country of Publication:
- United States
- Language:
- English
Similar Records
Overview of high gradient SRF R&D for ILC cavities at Jefferson Lab
Q0 Improvement of Large-Grain Multi-Cell Cavities by Using JLab's Standard ILC EP Processing