Microphonics Measurements in SRF Cavities for RIA
Phase stabilization of the RIA drift tube cavities in the presence of microphonics will be a key issue for RIA. Due to the relatively low beam currents (lte 0.5 pmA) required for the RIA driver, microphonics will impact the rf power required to control the cavity fields. Microphonics measurements on the ANL Beta=0.4 single spoke cavity and on the ANL Beta=0.4 two-cell spoke cavity have been performed many at high fields and using a new "cavity resonance monitor" device developed in collaboration with JLAB. Tests on a cold two-cell spoke are the first ever on a multi-cell spoke geometry. The design is essentially a production model with an integral stainless steel housing to hold the liquid helium bath.
- Research Organization:
- Thomas Jefferson Lab National Accelerator Facility
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC05-84ER40150
- OSTI ID:
- 955401
- Report Number(s):
- JLAB-ACC-03-97; 7691408; DOE/ER/40150-4432
- Country of Publication:
- United States
- Language:
- English
Similar Records
Simulation Study of Electronic Damping of Microphonic Vibrations in Superconducting Cavities
Cavities and Cryomodules for the RIA Driver Linac
Electronic Damping of Microphonics in Superconducting Cavities
Conference
·
Sun May 01 00:00:00 EDT 2005
·
OSTI ID:840008
Cavities and Cryomodules for the RIA Driver Linac
Journal Article
·
Wed Jun 23 00:00:00 EDT 2004
· AIP Conference Proceedings
·
OSTI ID:20653178
Electronic Damping of Microphonics in Superconducting Cavities
Conference
·
Fri Jun 01 00:00:00 EDT 2001
·
OSTI ID:783670