Aging of d-Limonene-cleaned assemblies. Final report
The performance of 1600 electronic circuit variables was monitored throughout an 8000-hour exposure to +160{degrees}F. The variables involve 36 electronic assemblies, cleaned with various solvents, including d-Limonene, as a replacement for trichloroethylene (TCE). The assemblies were divided into four groups, including a TCE-cleaned control group at room temperature. Of the three groups exposed at +160{degrees}F, one was cleaned in TCE, one was cleaned in d-Limonene, and one was kept in a saturated d-Limonene atmosphere. No performance degradation was observed with any of the groups, including the worst-case exposure in a saturated d-Limonene atmosphere.
- Research Organization:
- Allied-Signal Aerospace Co., Kansas City, MO (United States). Kansas City Div.
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC04-76DP00613
- OSTI ID:
- 95178
- Report Number(s):
- KCP--613-5568; ON: DE95016108
- Country of Publication:
- United States
- Language:
- English
Similar Records
Aging of D-limonene-cleaned assemblies
Compatibility of Halthane 88-3 urethane adhesive with the replacement cleaning solvent D-Limonene
Development of a replacement for trichloroethylene in the two-stage cleaning process
Technical Report
·
Thu Mar 31 23:00:00 EST 1994
·
OSTI ID:10170070
Compatibility of Halthane 88-3 urethane adhesive with the replacement cleaning solvent D-Limonene
Conference
·
Thu Aug 01 00:00:00 EDT 1991
·
OSTI ID:5270831
Development of a replacement for trichloroethylene in the two-stage cleaning process
Technical Report
·
Mon Nov 30 23:00:00 EST 1992
·
OSTI ID:10116492