Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

DWPF GLASS BEADS AND GLASS FRIT TRANSPORT DEMONSTRATION

Technical Report ·
DOI:https://doi.org/10.2172/950033· OSTI ID:950033

DWPF is considering replacing irregularly shaped glass frit with spherical glass beads in the Slurry Mix Evaporator (SME) process to decrease the yield stress of the melter feed (a non-Newtonian Bingham Plastic). Pilot-scale testing was conducted on spherical glass beads and glass frit to determine how well the glass beads would transfer when compared to the glass frit. Process Engineering Development designed and constructed the test apparatus to aid in the understanding and impacts that spherical glass beads may have on the existing DWPF Frit Transfer System. Testing was conducted to determine if the lines would plug with the glass beads and the glass frit slurry and what is required to unplug the lines. The flow loop consisted of vertical and horizontal runs of clear PVC piping, similar in geometry to the existing system. Two different batches of glass slurry were tested: a batch of 50 wt% spherical glass beads and a batch of 50 wt% glass frit in process water. No chemicals such as formic acid was used in slurry, only water and glass formers. The glass beads used for this testing were commercially available borosilicate glass of mesh size -100+200. The glass frit was Frit 418 obtained from DWPF and is nominally -45+200 mesh. The spherical glass beads did not have a negative impact on the frit transfer system. The transferring of the spherical glass beads was much easier than the glass frit. It was difficult to create a plug with glass bead slurry in the pilot transfer system. When a small plug occurred from setting overnight with the spherical glass beads, the plug was easy to displace using only the pump. In the case of creating a man made plug in a vertical line, by filling the line with spherical glass beads and allowing the slurry to settle for days, the plug was easy to remove by using flush water. The glass frit proved to be much more difficult to transfer when compared to the spherical glass beads. The glass frit impacted the transfer system to the point that the test apparatus had to be disassembled to dislodge the plugs created in the system.

Research Organization:
SRS
Sponsoring Organization:
DOE
DOE Contract Number:
AC09-08SR22470
OSTI ID:
950033
Report Number(s):
SRNL-STI-2008-00412
Country of Publication:
United States
Language:
English

Similar Records

Glass Frit Clumping and Dusting
Technical Report · Wed Sep 25 20:00:00 EDT 2013 · OSTI ID:1097231

Yield Stress Reduction of DWPF Melter Feed Slurries
Conference · Sun Jul 01 00:00:00 EDT 2007 · OSTI ID:21229341

Potter's Industries tests of spherical frit