Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Two-phase pressure drop, boiling heat transfer, and critical heat flux to water in a small-diameter horizontal tube.

Journal Article · · Int. J. Multiphase Flow
Two-phase pressure drop, boiling heat transfer, and critical heat flux to water were studied in a small horizontal tube of 2.98-mm inside diameter and 0.91-m heated length. Experiments were performed at a system pressure of 200 kPa, mass fluxes of 50-200 kg/m{sup 2}s, and inlet temperatures from ambient to 80 C. Experimental results and comparisons with state-of-the-art predictive correlations are presented. Modifications were made to the Chisholm two-phase multiplier correlation and to the Argonne National Laboratory small-channel boiling heat transfer correlation to better predict the experimental data of the present study.
Research Organization:
Argonne National Laboratory (ANL)
Sponsoring Organization:
EE
DOE Contract Number:
AC02-06CH11357
OSTI ID:
949375
Report Number(s):
ANL/ET/JA-40399
Journal Information:
Int. J. Multiphase Flow, Journal Name: Int. J. Multiphase Flow Journal Issue: 6 ; Jun. 2002 Vol. 28; ISSN IJMFBP; ISSN 0301-9322
Country of Publication:
United States
Language:
ENGLISH

Similar Records

Critical heat flux and boiling heat transfer to water in a 3-mm-diameter horizontal tube.
Conference · Sun Dec 03 23:00:00 EST 2000 · OSTI ID:772124

Boiling heat transfer in a horizontal small-diameter tube
Journal Article · Sun Oct 31 23:00:00 EST 1993 · Journal of Heat Transfer (Transactions of the ASME (American Society of Mechanical Engineers), Series C); (United States) · OSTI ID:5675551

Boiling heat transfer of refrigerant R-113 in a small-diameter, horizontal tube
Technical Report · Tue Dec 31 23:00:00 EST 1991 · OSTI ID:10183555